background image

 

 

Copyright ©2020, Future Designs, Inc., All Rights Reserved 

User’s Manual

 

ELI70-INHW 

ELI70-IPHW 

ELI70-IRHW 

ELI70-INHW-M 

ELI70-IPHW-M 

ELI70-IRHW-M 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

                                 ELI70-IPHW 

ELI70-IPHW-M (with mounting brackets) 

 
 
 
 
 

Revision 1.08 

 

 

Содержание ELI Series

Страница 1: ...Copyright 2020 Future Designs Inc All Rights Reserved User s Manual ELI70 INHW ELI70 IPHW ELI70 IRHW ELI70 INHW M ELI70 IPHW M ELI70 IRHW M ELI70 IPHW ELI70 IPHW M with mounting brackets Revision 1 08...

Страница 2: ...otice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Future Designs Inc 996 A...

Страница 3: ...ecommended Accessories Purchased Separately 5 ESD Warning 5 Determining the Revision of your ELI 5 Technical Specifications 6 Mechanical and Mounting Details 7 Connectors 8 Power Details 8 Extended Di...

Страница 4: ...rsions with different touch screen options ELI70 INHW No Touch Screen ELI70 IPHW PCAP Touch Screen ELI70 IRHW 4 wire Resistive Touch Screen Each of these products is also available in a M version with...

Страница 5: ...ables will be determined by the ELI mounting location and position in each user application ESD Warning Figure 1 Electrostatic Sensitive Device Our ELI units are shipped in a protective anti static pa...

Страница 6: ...PHW IRHW None PCAP 4 Wire Resistive Touch Screen Interface USB IPHW IRHW Only Touch Panel Hardness 3H Touch Panel Force 120gF max Active Area 152 4 W x 91 44 H mm Response Time 30ms Backlight 21 LED 7...

Страница 7: ...tails eli70 inhw m https www teamfdi com product details eli70 iphw m https www teamfdi com product details eli70 irhw m 3D Mechanical Models in both STEP and EASM format are available for customers a...

Страница 8: ...the T1071 P5P ND to be used for quick demos or prototyping across the entire ELI Family In general any 12VDC power supply with a 2 1mm center positive plug will be acceptable if it can provide enough...

Страница 9: ...634 can be found at http tinyurl com 1814634 To verify that the ELI is correctly powered you may check the 12VDC input with a Fluke meter or scope by probing the 12V and GND contacts shown below Pleas...

Страница 10: ...The frequency range for this signal is from 5KHz to 100KHz Each ELI unit s display backlight properties will vary so the user should test their version for an acceptable range of brightness control F...

Страница 11: ...ELI70 IxHW User s Manual 6 8 2020 Copyright 2020 Future Designs Inc Page 11 of 16 to generate the correct levels on the PWM Dimming Input Figure 5 ELI70 IxHW Backlight Curve in Nits...

Страница 12: ...source code must be compiled using g brightness cpp o brightness l bcm2835 in order to properly link the header file Must be run using sudo accessing GPIO pins requires root permissions After compili...

Страница 13: ...e between 0 and RANGE endl return 1 if bcm2835_init return 1 bcm2835_gpio_set_pad BCM2835_PAD_GROUP_GPIO_0_27 BCM2835_PAD_DRIVE_2mA Sets the drive current to 2mA bcm2835_gpio_fsel LED BCM2835_GPIO_FSE...

Страница 14: ...ge 14 of 16 Figure 8 Renesas Synergy S7G2 Signal and Ground The ELI backlight can also be controlled from a Renesas Synergy S7G2 wired as shown in Figure 8 The software for Synergy can be found on our...

Страница 15: ...M and ELI70 IRHW M come with brackets to provide additional mounting options The dimensions of the bracket and mounting holes are shown below for your reference If necessary the brackets can be remov...

Страница 16: ...com forum ELI70 INHW Product Page http www teamfdi com product details eli70 inhw ELI70 IPHW Product Page http www teamfdi com product details eli70 iphw ELI70 IRHW Product Page http www teamfdi com...