Specifications
Sampling Head and Flow
37 mm Filter holder, masking to 25 mm
Detector: Solid-state silicon 300-µm-depleted (450 mm² active area)
Pump: diaphragm-type, 7.0 LPM with no load
Alpha Data Analysis
MCA: 1024-channel analyzer binned to 256 channel spectrum
Alpha Peak-shape-fitting algorithm
Po-212, Po-214, Po-218, (optional one or two isotopes-of-interest)
Acute (fast response) and Chronic (high sensitivity) dose determinations
Typical 30% efficiency for Pu-239
Physical
Battery powered: 7.2V Lithium-Ion, 6.6Ah
Weight: 8.3 lbs (3.8 kg)
Dimensions: (W x H x D) 10 x 12 x 5 in.
Temperature: 0 to 122 °F (-17 to 50 °C)