Administering E1 and T1 Services
Verifying E1 and T1 parameter settings
MAX Administration Guide
5-21
PBX-T1 specific parameters
The VT100 interface of the MAX unit includes a NET/T1 menu. Specify T1 settings by using
five T1-specific parameters in the Line N subprofiles in the Line Config profile. You must
evaluate the settings of T1 parameters as you verify the proper configuration of the unit.
Table 5-11 summarizes the T1-specific parameters that are available if the MAX unit is
functioning in a PBX-T1 network environment.
T1-PRI:PRI #
Type
T1-PRI:PRI # Type is used for outbound calls made by the MAX unit
on PRI lines so that the switch can properly interpret the telephone
number dialed. Ask your PRI provider for details on when to use each
of settings. This parameter specifies the TypeOfNumber field in the
called party’s information element.
The value you specify for PRI # Type in the Dial Plan profile overrides
the value of T1-PRI:PRI # Type in the Line N profile if you have
enabled the unit’s Dial Plan profiles.
This parameter applies only to calls placed by devices terminating the
inband T1 lines provided by the MAX unit in a T1-PRI conversion con-
figuration.
T1-PRI:Num-
PlanID
T1-PRI:NumPlanID is used for outbound calls made by the MAX on
PRI lines so that the switch can properly interpret the telephone number
dialed. Ask your PRI provider for details on when to use each of the set-
tings. This parameter specifies NumberPlanID field in the called party’s
information element.
This parameter applies only to calls placed by devices terminating the
inband T1 lines provided by the MAX unit in a T1-PRI conversion con-
figuration.
The value you specify for NumPlanID in the Dial Plan profile overrides
the value of T1-PRI:NumPlanID in the Line N profile if you have
enabled the unit’s Dial Plan profiles.
Table 5-10. T1-PRI-specific parameters (continued)
Parameter
Description
Table 5-11. PBX-T1 parameters and settings
Parameter
Specifies
Add Number
Specifies a series of digits to add to the beginning of the dial-out tele-
phone number after removing the digits specified by Delete Digits. The
device connected to Line 2 (typically a PBX) dials this telephone num-
ber. This parameter applies only to T1 lines using PBX-T1 conversion.
Specify any digit string that the PRI switch requires. Contact your PRI
switch provider for more information about requirements.