Using Traps to Monitor Performance
Alarm/Error and Security events
MAX Administration Guide
9-15
Security events
Security events are used to notify users of security problems and track access to the unit from
the console. The MIB-II event authenticationError is a security event. The other security
events are Lucent-specific. The include:
Security event
Signifies
authenticationFailure
(RFC-1215 trap-type
4)
The MAX sending the trap is the addressee of a protocol message that
is not properly authenticated.
consoleStateChange
(ascend trap-type 12)
The console associated with the passed console index has changed
state. To read the console’s state, get
ConsoleEntry
from the
Ascend enterprise MIB.
portUseExceeded
(ascend trap-type 13)
The serial host port’s use exceeds the maximum set by the Max DS0
Mins Port parameter associated with the passed index (namely, the
interface number).
systemUseExceeded
(ascend trap-type 14)
The serial host port’s use exceeds the maximum set by the Max DS0
Mins System parameter associated with the passed index (namely, the
interface number).
maxTelnetAttempts
(ascend trap-type 15)
A user has failed in three consecutive attempts to log into this MAX
via Telnet.