Terminal-Server Administrative Tasks
Starting remote management sessions
MAX Administration Guide
3-7
Starting remote management sessions
Multilink Protocol Plus (MP+) uses Point-to-Point Protocol (PPP) encapsulation with
Lucent-specific extensions, as described in RFC 1934, to extend the capabilities of Multilink
Protocol (MP). MP+ supports session and bandwidth management, enabling the MAX unit to
connect to another unit by means of multiple channels. After an MP+ connection has been
established with a remote station (for example, by using the DO Dial command), start a remote
management session with that station by entering the Remote command in the following
format:
remote
station
For example:
ascend% remote lab17gw
During the remote management session, the user interface of the remote device replaces your
local user interface, as if you had opened a Telnet connection to the device. Enter Ctrl-\ at any
time to terminate the remote session. Either end of an MP+ link can terminate the session by
hanging up all channels of the connection.
call terminated
N1
packets sent
N2
packets
received
This message indicates the number of packets sent (N1)
and received (N2).
cannot handshake
The MAX answered the outgoing call, but the two sides
did not properly identify themselves. Can indicate that the
call was routed to the wrong MAX module or that the tele-
phone number was incorrect.
frame-count must be in
the range 1-65535
The number of frames requested exceeded 65535.
no phone number
You did not specify a telephone number on the command
line.
test aborted
The test was terminated (Ctrl-C).
unit busy
You attempted to start another test when one was already
in progress. Run only one self-test at a time.
unknown items on
command-line
The command line contained unknown items. Inserting
one or more spaces in the telephone number can generate
this error.
unknown option
option
The command-line contained the option specified by
option, which is invalid.
unknown value
value
The command-line contained the value specified by value,
which is invalid.
wrong phone number
A device other than the MAX answered the call. There-
fore, the telephone number you specified was incorrect.
Message
Explanation