B-18
MAX Administration Guide
Diagnostic Parameters and Commands
Using diagnostics-related DO commands
> coredump enable 1.1.1.1
coredump over UDP is enabled locally only with server 1.1.1.1
> coredump disable 1.1.1.1
coredump over UDP is disabled locally only with server 1.1.1.1
> coredump
coredump over UDP is disabled locally only with server 1.1.1.1
> coredump enable 200.200.28.193
coreDump: Sending arp request...
coreDump: Sending arp request...
coreDump: Sending arp request...
coreDump aborted: Can’t find ether address for first hop to
200.200.28.193
Diag
Description: Indicates the whether the modules installed in the MAX unit are currently
running diagnostics.
Usage: Enter
diag
at the MAX prompt.
Example:
> diag
Listing all modules with diag ON:
callback debug is ON
>
Diag ?
Description: Displays a set of commands that use a common prefix,
diag
.
Usage: Enter
diag ?
at the prompt.
Example:
> diag ?
Listing all available diag modules:
addrpool ( Internet Protocol )
atmp ( Ascend Tunnel Mgmt Protocol )
bacp ( PPP Bandwidth Allocation Control )
bacpcm ( PPP Bandwidth Allocation Control )
brouter ( Operating System )
callback ( Operating System )
callrout ( Call Control )
chanstat ( Call Control )
dnissnmp ( SNMP )
flash ( PCMCIA Driver )
fr1490 ( Frame Relay )