B-48
MAX Administration Guide
Diagnostic Parameters and Commands
Using diagnostics-related DO commands
The first message indicates whether any RADIUS requests have been dropped by the MAX.
With this particular message, no requests were dropped. 1557 were sent successfully:
nSent[OK,fail]=[1557,0], nRcv=1557, nDrop[QFull,Other]=[0,0]
The next message indicates whether any session timeouts resulted from failure to receive a
RADIUS responses were not received, causing a session timeout. The message also indicates
responses that are received by the MAX but that do not match any expected responses. The
MAX keeps a list of sent requests, and expects a response for each request. In the following
message, one response received from the RADIUS server did not match any of the requests
that the MAX had sent out. This might be caused by a corrupted response packet, or by the
MAX timing out the session before the response was received.
nRsp[TimOut,NoMatch]=[0,1], nBackoff[new,norsp]=[0,0]
The following messages display a summarized list of RADIUS server statistics:
Local Rad Serv Stats:
unkClient=0
index 0 #Sent = 0, #SendFail=0 badAuthRcv = 0, badPktRcv = 0
Reset
Description: Resets the MAX, which terminates all active connections and restarts. All users
are logged out and the default security level is reactivated. All active WAN lines are
temporarily shut down because of the loss of signaling or framing information. As the MAX
boots, it runs its power-on self tests (POST).
Usage: Enter
reset
at the command prompt.
Example: To reset the unit:
>
reset
See Also: NVRAM
Revision
Description: Displays a MAX unit’s hardware revision level and serial number.
Usage: Enter the
revision
at the command prompt. The unit’s response contains five
elements:
[
HW_REV N NN SN
]
Element
Definition
HW_REV
The unit’s hardware revision, represented a number
0
to
9
.
A value of
0
(zero) specifies that the hardware revision is unknown.
This is not a cause for concern.
N NN
Information that Lucent Technologies uses internally.
SN
The serial number of the MAX unit.
Note:
For MAX 3000 units, this information determines whether you
can downgrade from the current version of operating system software.