Diagnostic Parameters and Commands
Using diagnostics-related DO commands
MAX Administration Guide
B-39
Example:
> lcstate
LANCORE state display is now ON
LANCORE state display is now ONLANCORE-257: incoming call
LANCORE-257: >> msg ’INCOMING’ in state ’AVAILABLE:A’
LANCORE-257: _availableIncomingCall
LANCORE:_enterIncomingCallStateA: routeID:257
LANCORE-257: No profile found (optional).
LANCORE-257: << new state is ’INCOMING:A’
LANCORE-257: call complete, status=SUCCESS, 1 channels
LANCORE-257: >> msg ’COMPLETE’ in state ’INCOMING:A’
LANCORE-257: _incomingCallComplete, success = SUCCESS
No coreInfo->miscInfo:route=257,mgmtType=0,wanProtocolType=255
LANCORE-257: wan complete
LANCORE-257: << new state is ’INCOMING:D’
LANCORE-257: _incomingWanOpenComplete, success = 1
LANCORE-257: >> msg ’WAN OPEN COMPLETE’ in state ’INCOMING:D’
LANCORE-257: _incomingWanOpenComplete, success = 1
LANCORE-257: << new state is ’INCOMING:B’
LANCORE-257: wan detect
LANCORE-257: >> msg ’WAN DETECT’ in state ’INCOMING:B’
LANCORE-257: _incomingWanUp
_incomingWanUp:userProtocol=0,mgmtType=2
LANCORE-257: << new state is ’IDLE:A’
MdbStr
Description: Modfies the default modem AT command strings used by the modems on a
MAX unit for both incoming and for outgoing calls. WIth earlier software, you could not
modify the AT command for modems on the unit. You could affect the string in minor ways by
modifying the V42/MNP, Max Baud, and MDM Trn Lvl parameters located in Ethernet > Mod
Config > TServe Options.
The MdbStr command also allows you to return the string to its factory default settings.
The modem chip in a MAX unit supports AT commands of up to 56 characters in length. To
fully support all possible functionality, each AT command is sent as two separate strings.
Modify one or both strings.
Note:
The AT command string initializes the modems it affects. When you change the AT
command string, you are changing the functionality of the modems. Please use the MdbStr
command carefully.
Following are the two default strings for the MAX unit:
•
AT&F0&C1V0W1X4
•
AT%C3\N3S2=255S95=44S91=10+MS=11,1,300,33600A
Usage: mdbstr [0] [1] [2] [
AT command string
]
Example: Modify each portion of the AT command string as follows:
Override the existing first string with a new string: