Installing a Stinger FS or Stinger FS+
Dressing the cables
Stinger® FS/Stinger FS+ Getting Started Guide
2-11
Figure 2-9. Gigabit Ethernet connection to an IP2100 control module
Use the following procedure to install and connect the SFP module in a Gigabit
Ethernet port of an IP2000 or IP2100 IP control module.
1
Align the SFP module so the edge connector is on the right (not visible in
Figure 2-9).
2
Slide the SFP module into the port.
Note
The SFP module slides into the port of an IP2100 at an upward angle. The
SFP module slides into the port of an IP2000 at a 90° angle to the face of the unit.
3
Press firmly to seat the SFP module.
4
Align the LC connector on optical cable so the locking connector is on the left.
(See Figure 2-9.)
5
Slide the optical connector into the SFP module until the locking connector
engages with a slight click.
For additional details, see “Optical connectors” on page B-3 and “SFP modules” on
page B-3.
Dressing the cables
After connecting the cables to the LPMs and trunk modules in the rear of the chassis,
dress the cables down and thread them through the cable management brackets of
the Stinger FS or Stinger FS+ chassis as shown in Figure 2-10.
16
16
15
15
14
14
13
13
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
STINGER FS
+
1
1
MASTER
MAJOR
MINOR
PC CARD
1
2
TRUNK ST
ATUS
1
3
4
6
ETHERNET
L/A
SPD
DIAG PORT
ALARM INPUT
GIGE-0
GIGE-1
LINK
ACT
GIGE-0
GIGE-1
MASTE
R
MAJOR
MINOR
PC CARD
1
2
TRUNK ST
ATUS
1
3
4
6
ETHERNET
L/A
SPD
DIAG PORT
ALARM INPUT
GIGE-0
GIGE-1
LINK
ACT
GIGE-0
GIGE-1
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
TX
CD
FAUL
T
1
2
3
4
5
6
7
8
9
10
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
LNK A
CT
ALARM INPUT
GIGE-0
GIGE-1
LINK
ACT
GIGE-0
GIGE-1
Fiber optic LC connector
SFP module
Locking connector