Verifying Connectivity
Issue 1 August 1996
35
Startup Screen
Verify that the Proxy Agent is connected to the PBX when you start Fault
Management as follows:
1. Follow your normal startup procedure.
2. When the Fault Management Startup screen displays, examine the
startup message.
n = a number
NOTE:
Neither of these messages display if the Refresh Proxy Agent On
Startup field on the Setup screen is set to FALSE. (You can access
this screen from the Options menu on the Switch View screen.)
The startup screen displays for a brief time. So, if you cannot read these
messages, you can verify connectivity by refreshing data while Fault
Management is running. (This process is described in the next section.)
Do not rely on the following message that displays on the Switch View to
verify connectivity:
SUCCESS all data retrieved from switch!...
If the message is …
Then the
connection is …
Refresh in progress, estimated
delay nnn seconds, nnn seconds
elapsed.
Up
Refresh on Startup Failed!
Continuing with Cache Data.
Down