I-2
1/19/05
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
About Trunk Conditioning
Beta Draft Confidential
The LPort configuration parameters enable trunk conditioning, only if a buffer
underflow or overflow situation occurs on the receiving end from ATM network.
lists the range of value and default values for trunk conditioning parameters.
Structured Service With NxDS0 Bundle
In the structured service case, when loss of signal (LOS), Out-of-Frame (OOF) alarm,
or alarm indication signal (AIS) is detected in the downstream signal, trunk
conditioning is carried out per DS0 bundle in the downstream direction and a remote
alarm identification (RAI) is sent in the upstream direction.
Table I-1.
Trunk Conditioning Recommended Tx and Rx Values
Field
Value
Default
Tx Conditioning Data
0 to 0xFF
0x7F
Tx Conditioning Signal
0 to 0xF
0
Tx Conditioning Mode
1 (None)
2 (Data and Signaling)
3 (Data)
4 (Signaling)
2 (Data and Signaling)
default
Tx Force Conditioning Mode
1 (None)
2 (Data and Signaling)
3 (Data)
4 (Signaling)
1 (None) default
Rx Conditioning Data
0 to 0xFF
0x7F
Rx Conditioning Signal
0 to 0xF
0
Rx Conditioning Mode
1 (None)
2 (Data and Signaling)
3 (Data)
4 (Signalling)
1 (None) default
Rx Force Conditioning Mode
1 (None)
2 (Data and Signaling)
3 (Data)
4 (Signaling)
1 (None) default
Содержание CBX 3500
Страница 888: ......