15-10
1/19/05
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Configuring RLMI
Configuring the RLMI Switchover Mode
Beta Draft Confidential
3. If desired, select the Switchover Mode field’s pull-dow list, which indicates the
mode of operation for automatic bindings when an interface changes up/down
states. You can configure the Switchover Mode field only when the Master/Slave
Mode field is configured as Master. Options include:
•
Manual Only – No switchover occurs when a link goes down or up. A
switchover can occur only by a manual NMS-forced switchover.
•
Full Revertive – (default) Reverts to primary binding when primary is up.
•
Semi Revertive – Remains on backup binding when primary is up.
4. Choose OK.
Note – To add a circuit connection and configure endpoints for an RLMI PVC
connection, see
“Defining a Point-to-Point Circuit Connection” on page 10-13