Configuring CBX or GX Logical Ports
Setting Logical Port Attributes
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
1/19/05
3-23
CDV (
µ
secs)
(0-5000)
(supported on
OPTimum trunk
LPorts)
Enter a CDV value (in
µ
secs) that will be added to the Lucent
default trunk CDV. For CBR traffic, this default is 250
µ
secs. For
VBR traffic, the default value is 500
µ
secs.
The logical port CDV value is zero (0) by default. If you believe
that the path through the network providing the OPTimum trunk
connectivity will introduce additional CDV (exceeding the value
provided by the Lucent default), enter the appropriate value in this
field.
Enable Path Trace
Select the check box to enable path trace for circuits that pass
through this logical port.
Clear the check box (default) to disable path trace.
For more information on configuring and viewing Path Trace, see
Chapter 12 of the Switch Diagnostics User’s Guide for
CBX 3500, CBX 500, GX 550, and
B-STDX 9000.
CrankBack Info
Required
Select the check box to enable collection of crankback information
for circuits that pass through this logical port. Crankback
information is information about dynamic rerouting of call setups
around failed nodes or links (or links with insufficient resources) on
the traced path.
Clear the check box (default) to disable crankback information
collection.
Pass Along Request
Select the check box to enable (default) pass along request for
circuits that pass through this logical port. When the path trace
continues through nodes that do not support the path trace feature,
the trace results may contain some gaps between successive entries
of logical nodes and logical ports traversed by this connection or
party.
Clear the check box to disable pass along request. The path trace
will terminate at any switch that does not support the path trace
feature. A partial path trace will be returned.
Path Trace Timeout
(1-65535)
Enter the number of seconds for which you want the trace results to
be maintained in the switch. Enter a value between one and 99,999
or accept the default value (600).
Maximum Records
(1-200)
Enter the number of trace records that can be present for this LPort.
Enter a value between one and 200, or accept the default value (20).
Table 3-3.
Add Logical Port: Administrative Tab Fields (Continued)
Field
Action/Description