Beta Draft Confidential
18-32
1/19/05
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Configuring SPVCs
Defining a PMP SPVC (Offnet Circuit)
Selecting an Endpoint From a Physical Port
To select an endpoint from a physical port:
1. In the Select Endpoint dialog box, expand the node for the desired switch for the
endpoint.
2. Expand the Cards node.
3. Expand the node for the desired card.
4. Expand the PPorts node.
5. Expand the node for the desired physical port.
6. Expand the LPorts node.
7. Select the desired LPort.
8. Choose OK and continue with
“Configuring Offnet PMP PVC Root Parameters”
in the next section.
Configuring Offnet PMP PVC Root Parameters
To configure offnet point-to-multipoint PVC root parameters, you enter information in
each of the following tabs, categorized by parameter type:
•
Administrative (
•
Traffic Type (
•
NDC (
•
Accounting (
•
Path (