D-2
APX 1000™ Getting Started Guide
Safety-Related Electrical, Physical, and Environmental Information
Electronic and electrical specifications
Electrical requirements
The APX 1000 can be powered from a dc or ac power source, or both. The power source is
wired to the power supplies on the right side at the rear of the chassis. Although a single ac or
dc power supply is sufficient to operate the unit, it can be equipped with two power supplies of
either type, or one power supply of each type in combination.
Table D-1 lists the APX 1000 electrical requirements.
Because the APX 1000 configuration profiles are stored in NVRAM, they are not lost when
the unit is turned off.
Ground wire size
Table D-2 lists the chassis ground wire specifications for APX 1000 units.
Table D-1. APX 1000 electrical requirements
Element
Value
Voltage
ac: 100Vac to 240Vac (50/60Hz, single phase)
dc: -36Vdc to -72Vdc at the terminals (-48Vdc to -60Vdc
nominal)
Maximum Current
Current must not exceed:
ac: 8 amps (at 100Vac) to 4 amps (at 240Vac)
dc: 18 amps
Input Protection
ac: 10-amp fuse internal (not user accessible)
dc: 25-amp integral circuit breaker and power switch
Table D-2. Ground wire size
Product
AWG Size
Cross-sectional
area (mm
2
)
Terminal Lug
(Panduit part No.)
APX 1000 (ac)
12 AWG
4.0 mm
2
PV12-14HDR-L
(or equivalent)
APX 1000 (dc)
12 AWG
4.0 mm
2
PV12-14HDR-L
(or equivalent)
APX 1000 (dc)
8 AWG
3.25 mm
2
LCD8-14DH-L
dual hole lug
(or equivalent)