4.
Parameters
4-5
(2)
Example of changing speed control mode to position control
mode ( [P0-03]: 00001 -> 00002 )
Ord
er
Loader Displays
Keys to Use
What to Do
1
Displays the speed control mode with
main power and control power
permitted.
2
Press [MODE] to move to [P0-00].
3
Press [UP] or [DOWN] to move to [P0-
03].
4
Press [SET] to go to the parameter edit
window. The parameter is displayed as
00001.
5
Press [UP] or [DOWN] at the blinking
cursor to change the number to 00002.
6
Press and hold [SET] for approximately
one second. After two flickers, the
number will be saved as 00002 in the
parameter.
7
Press and hold [MODE] for
approximately one second to return to
the P0-03 parameter.
8
Press [MODE] to change status to
position operation [P= bb] status which
is the summary display of the current
status.
NOTE 1)
“ ” indicates flickering.
If you hold down [UP] / [DOWN] at the current cursor in the parameter window, the number continues to
increase/decrease.
Содержание XDL-L7SA001X