3. Wiring Method
3-4
3.2
Power Wiring
3.2.1
XDL-L7 Drive Wiring Diagram [XDL-L7SA001
□
-
XDL-L7SA035
□
]
U
V
W
L1
L2
L3
C1
C2
B+
B
BI
38
39
CN1
RA
M
E
Alarm-
Alarm+
1Ry
RA
1SK
1Ry
1MC
+24V
NF
1MC
R S T
서보드라이브
(200~230V)
Main
OFF
Main
ON
인코더
외부
회생저항
주1)
주2)
PO PI
DC 리액터
NOTE 1)
It takes approximately one to two seconds until alarm signal is output after you turn on the main
power. Accordingly, push and hold the main power ON switch for at least two seconds.
Short-circuit B and BI terminals before use. Regenerative resistance of XDL-L7SA001
□
-XDL-L7SA004
□
(50
[W], 100 [
Ω
]), XDL-L7SA010
□
(100 [W], 40 [
Ω
]), and XDL-L7SA035
□
(150 [W], 13 [
Ω
]) exist inside.
If regenerative capacity is high because of frequent acceleration and deceleration, open the short-
circuit pins (B, BI) and connect external regenerative resistance to B and B+.
Remove approximately 7-10 [mm] of the sheath from the cables for the main circuit power and attach crimp
terminals. (Refer to “3.2.2 Power Circuit Electric Sub Assembly Standards.”)
Connect or remove the main circuit power unit wiring after pushing the button of the XDL-L7SA001
□
– XDL-
L7SA010
□
drive terminal. For XDL-L7SA035
□
drive, use a (-) slot screwdriver for connection and
removal.
Servo Drive
Note 1)
DC Reactor
Encoder
Note 2) External
Regenerative Resistance
7~10
㎜
Содержание XDL-L7SA001X
Страница 2: ......
Страница 38: ...2 Installation 2 6 ...
Страница 48: ...3 Wiring Method 3 10 3 3 Example of connecting to PLC 3 3 1 XGT PLC 1 XGF PO1 2 3A Open Collector ...
Страница 63: ...3 Wiring Method 3 25 3 7 Serial Encoder Signaling Unit CN2 Wiring 3 7 1 XLCS E CS Cable 3 7 2 XLCS E DS Cable ...
Страница 68: ......
Страница 142: ......
Страница 166: ......
Страница 232: ...7 Product Specifications 7 48 FCL Series XML FCL04A FCL03D FCL06A FCL05D FCL08A FCL06D FCL10A FCL07D ...