4. Parameters
4-42
Parameter
Unit
Initial
Details
Code
Name
Minimum
Maximum
P3-13
Program JOG operation
speed 1
[RPM] 0
Sets operation speed/operation time for programs 1
to 4 during program JOG operation [Cn-01].
A test run repeats from step 1 to step 4.
Sets operation speed ([P3-13]-[P3-16]) and
operation time ([P3-17]-[P3-20]) for each step.
E.g.) Step 1 operation
Program jog speed 1
-6000
6000
P3-14
Program JOG operation
speed 2
[RPM] 3000
Program jog speed 2
-6000
6000
P3-15
Program JOG operation
speed 3
[RPM] 0
Program jog speed 3
-6000
6000
P3-16
Program JOG operation
speed 4
[RPM] -3000
Program jog speed 4
-6000
6000
P3-17
Program JOG operation
time 1
[ms] 500
Program jog time 1
0
65535
P3-18
Program JOG operation
time 2
[ms] 5000
Program jog time 2
0
65535
P3-19
Program JOG operation
time 3
[ms] 500
Program jog time 3
0
65535
P3-20
Program JOG operation
time 4
[ms] 5000
Program jog time 4
0
65535
Содержание XDL-L7SA001X
Страница 2: ......
Страница 38: ...2 Installation 2 6 ...
Страница 48: ...3 Wiring Method 3 10 3 3 Example of connecting to PLC 3 3 1 XGT PLC 1 XGF PO1 2 3A Open Collector ...
Страница 63: ...3 Wiring Method 3 25 3 7 Serial Encoder Signaling Unit CN2 Wiring 3 7 1 XLCS E CS Cable 3 7 2 XLCS E DS Cable ...
Страница 68: ......
Страница 142: ......
Страница 166: ......
Страница 232: ...7 Product Specifications 7 48 FCL Series XML FCL04A FCL03D FCL06A FCL05D FCL08A FCL06D FCL10A FCL07D ...