Chapter 4. Basic instructions
4-1
4 Basic instructions
4.1
Contact instructions
4.1.1
LOAD, LOAD NOT, OUT
LOAD
LOAD NOT
OUT
Available Device
Flag
Instructions
M
P
K
L
F
T
C
S
D
#
D Integer
Steps
Error
(F110)
Zero
(F111)
Carry
(F112)
LOAD
LOAD NOT
O O
O O
O O O
O
OUT
D
O O
O O
*
O
1
* Available only when do not use computer link module or data link module
1) LOAD
a) Functions
-
Starts a NO contact.
-
Draw the on/off data of the specified device ( ) and use the data as an operation result.
2) LOAD NOT
a) Functions
-
Starts a NC contact.
-
Draw the on/off data of the specified device ( ) and use the data as an operation result.
3) OUT
a) Functions
-
Outputs the operation result to the specified device ( ).
-
Several OUT instructions can be used in parallel with one operation result.
LOAD
OUT
LOAD NOT
S
S
D
S
S
S
S
S
D
D