Chapter 5. Application instructions
5-116
-
An instruction error occurs when the assress [ S+n2 ] or [ D+n2 ] is out of the range of specified
device.
-
Execution conditions
2) Program example
-
Program that read 14 words which begin with D1234 of self station, and write the read data to the
block which begin with D5678 of remote station (Station No. of FUEA module = h2F) through the
FUEA module at slot number 3 of self station. The link status is stored at the K015 word.
(System configuration is same as the example of READ instruction.)
Input condition
WRITE
Executed only once
Executed only once
[ D ]
‘n2’ words
Remote station
FUEA
module
Station
No.=’St’
[ S ]
‘n2’ words
Self-station
FUEA
module
at
slot No.
= ‘n1’
Link status
[ SS ]
WRITE h0003 h002F D1234 D5678 h0014 K015
D5678
14 words
Remote station
FUEA
module
Station
No.=h1D
14 words
Self-station
FUEA
module
Slot No.
= 02
Link status
D1234
K015