Chapter 5. Application instructions
5-118
-
An instruction error occurs when the assress [ S+n2 ] or [ D+n2 ] is out of the range of specified
device.
-
Execution conditions
2) Program example
-
Program that reads 10 words, through the FUEA module mounted at the slot 03, from the address
10 of the buffer memory of the K1000S A/D module mounted at the slot 01 of remote station h1D,
and stores the read data to the 10 words which begin with D0300 of self station. The link status is
stored at M020 word of self station.
‘n2’ words
Self-station
FUEA
module
at
slot No.
= ‘sl’
Link status
[ D ]
[ SS ]
[ S ]
‘n2’ words
Remote station
FUEA
module
Station
No.=’St’
Buffer memory of
special function module
Input condition
RGET
Executed only once
Executed only once
10 words
Self-station
FUEA
module
at
slot No.
= 03
Link status
D0300
M020
10
10 words
Remote station
FUEA
module
Station
No.=h1D
Buffer memory of A/D
module at slot 01
RGET h0003 h011D D0300 h0010 h0020 M0020