TROUBLE SHOOTING GUIDE
NO DISPLAY AT REAR OF HANGER ASSEMBLY
Ensure 120vac power to fixture is live and on a non-dimmed line.
Remove DMX connectors and inspect contact pins for damage and signs of
corrosion
Inspect 120 volt U ground supply wire for cuts or mechanical damage
Inspect U ground plug contacts.
Power switch is on (up position)
FIXTURE DOESN’T RESPOND TO ANY FUNCTIONS
REQUESTED FROM HAND CONTROLLER
Establish power is correct and display is functioning properly, see above.
Test with another hand controller if available. If still unresponsive proceed
to next step.
Remove DMX connectors and inspect contact pins for damage and no signs
of corrosion. Note all five wires and pins are required to operate hand
controller.
Check hanger display for proper addressing and mode. For use with hand
controller the fixture display must show the “F” prefix; not the three digit
DMX channel and the display must not be flashing.
It is important to note that the LRX fixture will not begin responding to a
newly selected FIXTURE/DMX address until it has been stored by pressing
and holding the store (round icon) button. If the display is flashing, this is
a warning that the displayed FIXTURE/DMX address does not match the
address that the fixture is currently responding to.
Plug hand controller directly into fixture, at this point the hand controller
should light up and DMX light on the fixture should also light up. At this
point if the unit is not operational test with another hand controller.
Ensure the address at the fixture matches the address on the hand
controller.
If still not operational, place fixture into DMX mode and test with an
alternative DMX source.
Call for service
TILT, PAN OR FOCUS MOTOR
NOT OPERATING CORRECTLY.