LRX™ SCORPION
Check on line for the latest updates at www.lrx-lighting.com
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
3
3
Safety power lockout procedures must be followed.
Safe electrical and working practices must be observed.
WARNING
This fixture has rotating parts with pinch points.
Fixture may move without warning.
No personal within range of motion
Never operate with any covers missing.
WARNING
High energy light output will burn skin and ignite combustible materials. Do
not operate in the proximity of materials that are adversely affected by heat
or light.
Lamp housing becomes very hot when in operation.
Never look directly at the light source
When fixtures are mounted in close proximity to one another, care must be
taken so that output energy from one fixture is not directed at another
fixture or electrical cabling.
FIXTURE ADDRESSING
Fixture addressing is performed at the rear of the fixture hanger assembly.
The fixture can be programmed to operate in DMX mode or FIXTURE mode
(for use with the hand controller). Because each LRX fixture requires sixteen
DMX channels for operation, FIXTURE mode is merely a convenient way of
skipping DMX channels in 16 channel increments, beginning with DMX
channel #001. Additionally, fixture mode provides power to a connected hand
controller, which is also designed to work in 16 channel increments.
DMX Connector pin out: (also see important note below)
Pin 1 = ground
Pin 2 = Data negative
Pin 3 = Data positive
Pin 4 = 12VDC negative
Pin 5 = 12 VDC positive