7.9 The electric pump stops, and
then rotates in the wrong direction
Cause
Remedy
There is a leakage in
one or both of the
following components:
The suction pipe.
The foot valve or
the check valve.
Repair or replace
the faulty
component.
There is air in the
suction pipe.
Bleed the air.
7.10 The pump starts up too
frequently
Cause
Remedy
There is a leakage in
one or both of the
following components:
The suction pipe.
The foot valve or
the check valve.
Repair or replace
the faulty
component.
There is a ruptured
membrane or no air
pre-charge in the
pressure tank.
See the relevant
instructions in the
pressure tank
manual.
7.11 The pump generates too much
noise
Cause
Remedy
Pump
cavitation
Reduce the required flow
rate by partially closing the
on-off valve downstream
from the pump. If the
problem persists check the
operating conditions of the
pump (for example height
difference, flow resistance,
liquid temperature).
The motor
bearings are
worn.
Contact Xylem or the
Authorised Distributor.
There are
foreign
objects
inside the
pump
Contact Xylem or the
Authorised Distributor.
Impeller rubs
on the wear
ring
Contact Xylem or the
Authorised Distributor.
Coupling
misaligned
Check the coupling
alignment.
Flexible
elements of
the coupling
worn
Contact Xylem or the
Authorised Distributor.
Contact Xylem or the Authorised Distributor
with regard to any situations not covered here.
Содержание ESH ATEX
Страница 100: ...100 it en fr de es nl APPENDICE APPENDIX ANNEXE ANHANG APENDICE BIJLAGE 1 ESH_M0030_ATEX_A_sc...
Страница 111: ...111 it en fr de es nl 7 8 9 10 ESH_M0014_A_SC ESH_M0015_A_SC ESH_M0016_A_sc ESH_M0017_A_sc ESH_M0015_A_sc ESH_M0014_A_sc...
Страница 124: ...124 it en fr de es nl ESH_M0001_FLENDER_A_sc 23...
Страница 125: ...125...
Страница 126: ...Xylem Service Italia S r l Via Vittorio Lombardi 14 Montecchio Maggiore VI 36075 Italy 2017 Xylem Inc...