![LOVATO ELECTRIC DCRG8F Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/lovato-electric/dcrg8f/dcrg8f_instruction-manual_1941984016.webp)
I564 GB I 02 19
16
M19 - MISCELLANEOUS UoM Default Range
P19.01 Disconnection of steps when switching to MAN mode OFF OFF/ON
P19.02 Maintenance interval 1 h 9000 1 - 30000
P19.03 Maintenance mode 1 Always Always
Step inserted
P19.04 Maintenance interval 2 h 9000 1 - 30000
P19.05 Maintenance mode 2 Steps ins. Always
Steps inserted
P19.06 Maintenance interval 3 h 9000 1 - 30000
P19.07 Maintenance mode 3 Steps ins. Always
Steps inserted
P19.08 Number of maintenance insertions kcnt 120 OFF/ 1-200
P19.01
– If set to ON, when switching from AUT to MAN mode, steps are disconnected in sequence.
P19.02…P19.07
– Defines three intervals of scheduled maintenance. For each of the three intervals, the duration in hours and the counting mode can be set.
Always
= Count always active when the controller is powered.
Steps ins.
= Hour count is incremented only when one or more steps are inserted/connected. When the time elapses, alarms, respectively A20, A21, A22, are generated (alarms must be enabled).
P19.08
– Defines the number of operations of the steps (considering the step with the highest count) beyond which alarm A23 is generated. This parameter is valid only if contactors are used, not for thyristor
modules.
M20 - LIMIT THRESHOLDS (LIMn, n=1…16) UoM Default Range
P20.n.01 Reference measurement OFF OFF- (measurement)
P20.n.02 Channel number x 1 OFF / 1-99
P20.n.03 Function Max Max - Min - Min+Max
P20.n.04 Upper threshold 0 -9999 to +9999
P20.n.05 Multiplier x1 /100 to x100k
P20.n.06 Delay s 0 0.0 – 600.0
P20.n.07 Lower threshold 0 -9999 to +9999
P20.n.08 Multiplier x1 /100 to x100k
P20.n.09 Delay s 0 0.0 – 600.0
P20.n.10 Idle state OFF OFF-ON
P20.n.11 Memory OFF OFF-ON
Note: This menu is divided into 16 sections for the limit thresholds LIM1...16
P20.n.01
– Defines at which measurements supplied by DCRG8F to apply the limit threshold.
P20.n.02
– The channel is defined when the reference measurement is an internal multichannel measurement (AINx for example).
P20.n.03
– Defines the operating mode of the limit threshold.
Max
= LIMn enabled when the measurement exceeds P20.n.04 and P20.n.07 is the reset threshold.
Min
= LIMn enabled when the measurement is less than P20.n.07 and P20.n.04 is the reset threshold.
Min+Max
= LIMn enabled when the measurement is greater than P20.n.04 or less than P20.n.07.
P20.n.04 - P20.n.05
– Define the upper threshold, obtained by multiplying value P20.n.04 by P20.n.05.
P20.n.06
– Upper threshold tripping delay.
P20.n.07...P08.n.09
– As above but referred to the lower threshold.
P20.n.10
– Inverts the state of limit LIMn.
P20.n.11
– Defines whether the threshold remains latched and is cleared manually through commands menu (in ON) or if it resets automatically (in OFF).
M21 - COUNTERS (CNTn, n=1…8) UoM Default Range
P21.n.01 Count source OFF OFF-ON-INPx-OUTx-
LIMx-REMx
P21.n.02 Channel number x 1 OFF / 1-99
P21.n.03 Multiplier 1 1-1000
P21.n.04 Divisor 1 1-1000
P21.n.05 Description of the counter CNTn (Text - 16 characters)
P21.n.06 Unit of measure Umn (Text - 6 characters)
P21.n.07 Reset source OFF OFF-ON-INPx-OUTx-
LIMx-REMx
P21.n.08 Channel number x 1 OFF / 1-99
Note: This menu is divided into 8 sections for counters CNT1...8.
P21.n.01
– Signal that increments the count (on rising edge). It may be energised by the DCRG8F (ON), the exceeding of a threshold (LIMx), the activation of an external input (INPx), etc.
P21.n.02
– Channel number x with reference to the previous parameter.
P21.n.03
– Multiplier K. The counted pulses are multiplied by this value before being displayed.
P21.n.04
– Fractional K. The counted pulses are divided by this value before being displayed. If other than 1, the counter is displayed with 2 decimal points.
P21.n.05
– Counter description. 16-character free text.
P21.n.06
– Counter unit of measure. 6-character free text.
P21.n.07
– Signal that clears the count. As long as this signal is enabled, the count remains at zero.
P21.n.08
– Channel number x with reference to the previous parameter.
G
B