Doc: I437GB04_16.docx 09/03/2016
p. 36 / 37
Technical characteristics
AC power: terminals 53, 54
Us rated voltage
100 – 240V~
Operating limits
90 – 264V~
Frequency
45 – 66Hz
Drawn/dissipated power
100V~ 12,5VA, 7W
240V~ 16,5VA, 7,3W
Micro-interruption immunity time
(without expansion modules)
≤
40ms (110V~ )
≤
200ms (220V~ )
Micro-interruption immunity time
(with 3 expansion modules)
≤
20ms (110V~ )
≤
100ms (220V~ )
Recommended fuses
F1A (fast)
DC Power: terminals 26, 27
Rated battery voltage
12 – 48V=
Operating limits
7,5 – 57,6V=
Maximum drawn current
510mA a 12V=
260mA a 24V=
135mA a 48V=
Maximum drawn/dissipated power
6,5W
Recommended fuses
T3,15A (delayed)
Voltmeter inputs Line 1, Line 2 , Line3: terminals 1-4, 5-8 and 9-12
Ue max rated voltage
600VAC L-L (346VAC L-N)
Measuring range
50…720V L-L (415VAC L-N)
Frequency range
45…65Hz – 360…440Hz
Measurement type
True RMS (TRMS)
Measurement input impedance
> 0.55M
L-N
> 1,10M
L-L
Connection modes
Three-phase line with or without neutral balanced three-phase
Current measurng inputs: terminals 13-18
Ie rated current
1A~ o 5A~
Measuring range
For 5A range: 0,02 – 6A~
For 1A range: 0,02 – 1,2A~
Input type
Shunt resistors powered by external low voltage current transformer (5A).
Measurement type
True RMS (TRMS)
Permanent thermal limit
+20% Ie
Short duration thermal limit
50A for 1 sec
Burden
0,6VA
Measurement accuracy
AC voltage inputs
0,25% f.s.
1digit
Digital inputs: terminals : 39 – 47 and 48-52
Input type
negative
Input current
8mA
Low input signal
2,2V
High input signal
3.4V
Input signal delay
50ms
RS485 serial interface: terminals 22-25
Interface type
Isolated
Baudrate
programmable 1200…38400 bps
Real Time Clock
Reserve charge
Back-up capacitor
Operation without power voltage
Approximately 14 days
Outputs OUT1, OUT3 and OUT5: terminals 55-56, 58-59 and 61-62
Contact type
3 x 1 NO
Rating
AC1 – 12A 250V~
AC15 -1,5A 250V~
UL use data
B300
Maximum usage voltage
300V~
Electrical/mechanical time
1x10
7
/ 1x10
5
operations
Maximum current on terminals 55, 59 and 62
12A
Outputs OUT2, OUT4 and OUT6: terminals 56-57, 59-60 and 62-63
Contact type
3 x 1 NO
Rating
AC1 – 8A 250V~
AC15 -1,5A 250V~
UL use data
B300
Maximum usage voltage
300V~
Electrical/mechanical time
1x10
7
/ 1x10
5
operations
Maximum current on terminals 55, 59 and 62
12A
Outputs OUT7, OUT9, OUT10 and OUT 11: terminals 19-21, 30-32, 33-35 and 36-38
Contact type
1 in scambio
Rating
AC1 – 8A 250V~ DC1 – 8A 30V=
AC15 -1,5A 250V~
UL use data
B300
30V= 1A Auxiliary duty
Maximum usage voltage
300V~
Electrical/mechanical time
1x10
7
/ 1x10
5
operations