9.3.26 User address recording Enter: 700
Operations: (PROG
→
user password
→
#)
→
700
→
#.
Functions:
Record user address. User can record sounds for 4 seconds, which can be achieved by 'Record' key on
the control panel. While recording, the green indicator for recording is on. The recorder should face directly to the
recording microphone on the control panel ensuring sounds distinctive. After recording, the green indicator will be
off, and then the recording effect can be checked: Connect a horn to the control panel, press 'Play' key or input
command, and then you can hear the record. If the sound needs to change, just to perform the steps above again.
3
4. Notices before using
●
Disconnect the powers supply while open the cabinet.
●
Don't disassemble the control panel and the keypad panel randomly to avoid accidents and damages.
●
Please connect AC power to the control panel after ensuring the installation correct completely.
●
Please use standby power (accumulator) to ensure the control panel can work normally when electric network
fails.
●
If the user has any problem while using, call our company for help.
●
Work out a protection scheme based on user's protection zone requirements, then decide the type and rating of
the detector.
●
Confirm the installation position and wiring direction according to the specific environment. Make sure the
position invisible without affecting its reliability. It is better to wire in concealed way.
●
The construction scheme and engineering drawings must be filed for maintenance later.
5. System installation
5.1. General requirements of engineering installation
5.2. Control panel installation
●
Mount the keypad in a position convenient to operate, and mount the control panel in a position invisible and
convenient to connect AC power and telephone line.
●
Avoid obstacles around the antenna of control panel.
●
Please use standby power to ensure the control panel can work normally when electric network fails.
Note: Only professional engineering installer can install, connect power line and provide service.
5.4 Standby power connection
●
The control panel uses 12V/7.0Ah sealed lead-acid rechargeable battery as standby power.
●
There is a red and a black power cords with plugs in the master controller for standby power connection.
Connect the red power cord to the positive terminal of standby power and the black power cord to the negative
terminal of standby power.
18
9.3.27 Record playing Enter: 71 X
Operations: (PROG
→
user password
→
#)
→
71
→
X
→
#.
Parameters definition:
X=1~8 indicating 1~8 alarm type records playing. X=9 indicating user address playing.
Functions:
Connect a horn to the control panel, play 8 alarm type records and user address record. The recorder
9.3.28 Event record reading Enter: 80 XX
Operations: (PROG
→
user password
→
#)
→
80
→
XX
→
#.
Parameters definition:
XX=01~40 event records.
Functions:
The system stores 40 event records, which can be inquired by user any time. The system records alarm
in zones, but no fault alarm for AC power loss, low battery, phone line disconnected, etc.
Note:
XX=01~40 is event number in time order. The latest event number is 01, the rest are numbered in this way.
When the 40 records are restored, the latest event records replace the oldest event records. After inputting
commands successfully, alarm type indicator displays corresponding zone type. Press '#' key to switch zone
numbers and time messages which display on LED.
For example:
User wants to inquire about NO. 5 alarm record, input: (PROG
→
user password
→
#)
→
80
→
05
→
#,
then LED displays alarm zone number '- - 31' and 'Tamper' alarm indicator is on. Press '#'key to display '2006',
press '#' key again to display '0 2 2 7', press '#' key to display '1 9 5 0', press '#' key again to display '- - 31',
9.3.30 All zones bypass canceling Enter: 920
Operations: (PROG
→
user password
→
#)
→
920
→
#.
9.3.29 All zones bypassed Enter: 910
Operations: (PROG
→
user password
→
#)
→
910
→
#.
●
220VAC input, 15V/2A output, 50Hz transformer.
●
Connect 15V output port of transformer to '15VAC IN' of the control panel.
●
Transformer-secondary supplies power only for the control panel; can not share with other
units.
●
Total current of the detector and the control panel should be less than 2A.
●
Total current of the main power supply is offered overload protection by BX300 (1A) fast-blow
fuse. Do not substitute a higher rated fuse while replacing the fuse.
●
If AC power disconnects and the system is connected to standby power, the control panel
will alarm for AC power failure. AC indicator on keypad will be on, and buzzer will chirp twice
in every two minutes until chirps 15 times(30minutes) ; when AC power restores, AC power
indicator will be off.
5.3. AC power connection
Entry delay:
A period for user to enter detection area, activate the delay zone and disarm before the system
alarms. During the period,user can activate several specified zones (entry zone etc) without
alarm immediately. While exceeding the time, the system alarms if not disarmed. Zones with
entry delay refer 7.1 zone type instructions .
Exit delay:
A period for user to leave detecting area once the system armed. Zones with exit delay will not
Transformer
9.3.31 All detectors in wireless zones removing Enter: 930
Operations: (PROG
→
user password
→
#)
→
930
→
#.
9.3.32 All wireless remote controller removing Enter: 940
Operations: (PROG
→
user password
→
#)
→
940
→
#.
Functions:
After the operations, all wireless remote controllers are canceled; remote controller can not perform the