1. General

This is a new kind of intelligent security product. It transmits alarm information to the user via telephone network 
and  is  remotely  controlled  to  deal  with  emergencies  in  time,  ensuring  user's  personal  and  property  safety.  This 
product has complete functions, flexible
configuration, strong destroy protection and convenient operations, being suitable for residences, stores, factories, 
warehouses, banks, schools and hospitals, etc.

2. Main features and functions

Connect 8 or 16 programmable wired zones and 8 programmable wireless zones 

Connect 4 keypads at most, each of them can extend 2 programming wired zones 

Dial alarm center, user's cell phone or fixed telephone automatically with voice alarm while emergencies happen

Compatible with: ADEMCO 4+1 , Contact ID Communication protocol, it is capable of alarming in network or in 
personal phone alone

Field monitor function

5 wireless remote controllers at most

Anti-tamper of the control panel and keypad, anti-snipping of keypad communication line

Optional accessories: probes of fire-proof and theft-proof; glass break detector, etc

Wireless learn code function with simple usage

Keypad programming and LED display

Restore user's password to factory defaults by hardware and restore the system factory defaults by software

Dial the alarm system via external telephone to arm/disarm in other places

Record 40 latest alarm events

3 groups timed auto-arm/auto-disarm time setting

Malfunction alarm: AC power fail, low voltage and telephone line loss

Set real-time clock inside

User addresses recording function

Programmable relay output

3. Terms definitions

                  Detector:

 A  facility  that  detects  intrusion  and  abnormal  state  automatically  via  some  electric  or  physical 

methods  and  outputs  switch  signals  or  wireless  signals  to  the  system  for  disposal,  then  sends 
out alarm signals, such as infrared detector, smoke detector, etc.

Protection Zone:

 An area within the detection range of one or one ground detectors, described by numbers in the 

system.

               Bypass: 

Close one of the zones temporarily, so that it can not alarm while activating the zones freely.

          Arm-away: 

The armed state while going out. All the zones without bypass are in alarm state.

            Arm-stay:

 The armed state at night. All the zones are in alarm state except active zone. 

                    Disarm:

  Cancel  the  alarm  information  that  has  happened.  Close  the  entry/exit  zones,  active  zones, 

perimeter zones. Other zones are still in armed state.

        24-hour  zone:

  No  matter  armed  or  disarmed,  it  is  in  effective  detecting  status.  It  is  usually  used  in  fire  alarm, 

plunder alarm and other emergent alarm which can be cancelled only by password holder.

19

10. Wireless remote controller operation

Wireless remote controller have 4 keys which can achieve operations of 
arm  away/stay,  disarm  and  panic  alarm  without  user  password.  Press 
keys  on  the  remote  controller  towards  the  control  panel  to  perform 
corresponding operations.

9.3.34 System defaults restoring                                                                                       Enter: 960

Operations: (PROG

user password

#)

960

#.

Functions:

  After  the  operations,  all  parameters  restore  to  defaults  in  factory  setting  except  user  password  and 

9.3.35 Keypad logout                                                                                                            Enter: 990

Operations: (Program

user password

#)

990

#.

Functions:

 After keypad logout, the keypad can not perform any operation to the system .User can remove keypad 

from the control panel. Connect keypad to the control panel again for restoring the operation.

Note: 

If  remove  keypad  from  the  circuit  without  logout,  the  system  will  send  out  an  alarm  of  keypad  loss, 

Arm away

Arm stay

Disarm

Panic

10.1 Arm-away

Press  'Away'  key  on  the  wireless  remote  controller,  the  system  enters 
arm  delay  status,  status  indicator  on  keypad  keeps  on,  buzzer  beeps 
continuously. When arm delay is over, buzzer stops chirping.

10.2 Arm-stay

Press 'Stay' key on the wireless remote controller, the system enters arm 
delay status, status indicator on keypad flashes, buzzer chirps once. 

10.3 Disarm

Press 'Disarm' key, the system enters disarm status, status indicator on keypad is off, buzzer chirps once.

10.4 Panic 

Press 'Panic' key for 2 seconds, the system will alarm automatically .The zone number is 17 and type is 'Panic'.

9.3.33 Zone type initialization                                                                                            Enter: 950

Operations: (PROG

user password

#)

950

#.

11. Remote telephone operation

User can dial telephone number of the control panel, and perform the operations: arm away/stay, disarm and field 
monitor and hearing alarm types. 

Dial  telephone  number  of  the  control  panel  for  more  than  ringing  attempts  set.  The  system  will  answer 
automatically and announce the user with a sound 'Di'. Then user presses '# + 4 digits user pa 1 operation 
digit + #, the control panel will operate corresponding commands.

6 operation digits,1 means arm-away, 2 means arm-stay, 3 means disarm,4 means field monitor ,5 means hearing 
current alarm sounds,0 means hang-up / stop dialing to alarm. 

For example, user password is 1234. To disarm the control panel, user can press '# 1 2 3 4 #' after switching on the 
system.  If  the  operations  are  performed  correctly,  'Di'  will  be  heard  once.  If  the  operations  are  performed 
incorrectly, 'Di' will be heard twice.

Содержание LHD6000

Страница 1: ...er Shenzhen Longhorn Technology Co Ltd Add Longhorn Hi Tech Estate TongFuyu Industrial Avenue Longhua Shenzhen G D China Post number 518109 Tel 800 830 8196 Fax 86 755 28140429 E mail service long horn com Web address http www long horn com ...

Страница 2: ...INSTALLATION MANUAL ...

Страница 3: ...acked in a box as followed Open the box and check it carefully If finding deficiency please fetch the provider in time Note There are two anti tamper switches of control panel twenty four EOL resistances 2 2k two keys for cabinet of control panel telephone line telescopic antenna keypad anti tamper switch spring screw expansion pipe and keypad fixed iron stand connecting line installation frame ke...

Страница 4: ...5mAh Potential reasons Solutions Types of fault Code learn unsuccessful Different detectors use the same code learn The different carrier frequency of the detector and the control panel The detector does not work normally Cancel this zone check the code learn again make sure the detector code learn has not been used Change the detector and try again Confirm carrier frequency of the detector Cancel...

Страница 5: ...Weekly testing is required to ensure proper operation of the system 14 Troubleshooting The controller plug is not inserted in DC socket or it is not connected well Check the connection of the plug or replace the socket Check whether keypad is wired incorrectly or not and wire Keypad is wired incorrectly Telephone can not work normally as the system is connected into telephone network Few ringing a...

Страница 6: ...ATION OF USER ARM DISARM Number Operation of using keypad without password such as arm away disarm and arm stay User password to arm disarm by using keypad or remote telephone Operation code of Arm disarm by using keypad or remote telephone Remote controller arm disarm Alarm for disarm arm operation by using telephone numbers from 2 to 6 Using duress code to disarm press 98 to send a disarm inform...

Страница 7: ...to alarm user can press 3 to disarm and then press 1 to arm after hearing alarm voice 11 3 Telephone arm stay After hanging up the system press user password 2 to arm When emergencies happen user has to disarm first and then arm the system again For example if user password is 1234 press 12342 When the master controller dials to alarm user can press 3 2 to arm after hearing sound 11 4 Telephone fi...

Страница 8: ...ll in armed state 24 hour zone No matter armed or disarmed it is in effective detecting status It is usually used in fire alarm plunder alarm and other emergent alarm which can be cancelled only by password holder 19 10 Wireless remote controller operation Wireless remote controller have 4 keys which can achieve operations of arm away stay disarm and panic alarm without user password Press keys on...

Страница 9: ...ng Functions Connect a horn to the control panel play 8 alarm type records and user address record The recorder 9 3 28 Event record reading Enter 80 XX Operations PROG user password 80 XX Parameters definition XX 01 40 event records Functions The system stores 40 event records which can be inquired by user any time The system records alarm in zones but no fault alarm for AC power loss low battery ...

Страница 10: ... GND Z2 GND Wiring board figure 5 5 Keypad installation The keypad provides two modes of installation for various surroundings concealed installation fixed on the wall by 86 box wiring board and bracket and open installation fixed on the wall by screws Bracket installation figure 120 80 10 6 33 20 30 Bracket figure Unit mm Wall Bracket Gang socket Tamper switch Fixed card hole fixed iron stand Fix...

Страница 11: ...sketch Locating hole Terminal slot Anti tamper switch spring hole Card slot Buzzer hole Dial switch hole Interface slot Card slot Outlet slot 5 5 2 Surface installation Connect keypad to the control panel and fix the keypad on the wall through the four locating holes at the rear cover of keypad Keypad PCB wiring sketch CPU V_KEYGND Z2 GND Z1 B A V_AUX Buzzer Wiring slot Wiring terminal Dial switch...

Страница 12: ...re keypads to avoid address clash It can be reached by adjusting address dial up switch on keypad back See the table below Note Dial up switch ON terminal is ON another terminal is OFF 1 OFF OFF ON ON 2 ID OFF ON OFF ON 1 NO1 keypad 2 NO2 keypad 3 NO3 keypad 4 NO4 keypad 15 9 3 15 Date setting Enter 33 XXXX Operations PROG user password 33 XXXX Parameters definition XXXX is for date setting XXXX m...

Страница 13: ...s XX 00 no delay XX 01 10 seconds 5 11 Telescopic antenna installation When telephone line is lost in self checking status the control panel will alarm for telephone line lost Loss indicator will be on and buzzer chirps twice in every two minutes until chirps 15 times 30minutes When telephone line is restored Loss indicator will be off 4 Status indicator Keep on when the system is in arm away stat...

Страница 14: ...ts the system begins to accept user remote operation 9 3 6 Bell on off setting Enter 24 X Operations PROG user password 24 X Parameters definition X 1 on X 0 off The factory setting is X 1 on Functions User can choose using bell alarm or not Setting the bell it will be on when the system alarms otherwise only buzzer on keypad chirps 9 3 7 Timed auto arm auto disarm option Enter 25 X Operations PRO...

Страница 15: ...G user password 11 XY Y Bracket means in programming status it is not necessary to input PROG user password enter command status directly Parameters setting X 1 6 indicates 1 6 groups telephone 1 is alarm number of the alarm center 2 6 are personal phone numbers Y Y indicates phone number needed to dial 1 15 digits phone number is null in factory setting Functions The system can be set 6 groups of...

Страница 16: ...faultsvaluesrestoration Keypadlogout 36 X Y 40 X Y 61 X 62 X 63 X 64 X 65 X 66 X 70 0 71 X 80 X 910 920 930 940 950 960 990 X 1 3 NO Xauto disarmmoment Y hourminute 4digits X 01 16 16wirezonesand 09 16areextendedwire zones X 21 28 8wireless zones X 41 48 4keypads have8wirezones TypecodeY 1 8 X 21 28 NO Xdetectorin wirelesszone X 21 28 NO Xdetectorin wirelesszone X 1 5 NO Xwirelessremote controller...

Отзывы: