Communication between control panel and alarm center have two formats ADEMCO 4+1 and ADEMCO Contact
ID.The event code identifications as followed:
12. Answering alarm communication code
21
11.4 Phone field monitor........................................................................................................... 20
11.5 Hearing current alarm type................................................................................................ 20
11.6 Hang-up/stop alarm dialing............................................................................................... 20
12. Answering alarm communication code..................................................................................... 21
13. Limitations of the alarm system................................................................................................. 21
14. Troubleshooting....................................................................................................................... 21
15. Technical parameters............................................................................................................... 22
16. Diagrams of zone type setting................................................................................................... 23
00
01
02
11
~
15
21
~
25
98
99
NO.
100
110
121
131
132
134
151
301
302
401
441
521
145
382
570
455
ADEMCO Contact ID TABLE OF EVENT CODES
DEFINITION
Panic zone alarm
Fire zone alarm
Perimeter zone alarm
Active zone alarm
Entry/Exit zone alarm
Duress code, Duress zone alarm
Gas zone alarm
AC power failure
DC power low-voltage
Keypad loss
Arm/Disarm operation
Arm-stay operation
Auto-arm/disarm failing
Bell canceling function
Keypad Anti-tamper
Control panel anti-tamper
alarm. Anti-tamper zone alarm
137
Zone bypass operation, zone
/user is 99 represent all zones
bypassed or all zones bypass
canceling
ADEMCO Contact ID OPERATION OF USER
ARM/DISARM Number
Operation of using keypad without password
such as arm-away disarm and arm-stay
User password to arm/disarm, by using
keypad or remote telephone
Operation code of Arm/disarm by using
keypad or remote telephone
Remote controller arm/disarm
Alarm for disarm/arm operation by using
telephone numbers from 2 to 6
Using duress code to disarm, press 98 to
send a disarm information before duress
alarm information
Timed auto-arm/auto-disarm
ADEMCO 4+1 Table of event codes NO. Identification
NO.
1
2
3
4
5
6
7
8
DEFINITION
Plunder alarm, duress zone
Disarm
Arm
AC power failure
Battery low-voltage
Restore default
Fire alarm, including fire gas and panic zone
Rob alarm, Entry/Exit /Active/Perimeter/
Anti-tamper zone
Although it is an advanced design security system, it does not offer guaranteed protection against burglary, fire, or
other losses. Any alarm system, whether commercial or residential, is subject to compromise or failure-to-warn for
a variety of reasons. These include:
1. Intruders may gain access through unprotected openings or have technical sophistication to invalidate the
system.
2. Most detectors can not operate without power, so if AC power loss and backup power is void, the alarm system
can not work.
13. Limitations of the alarm system