6. Keypad panel composition
Keypad panel mainly consists of display range, alarm type indicators, power indicator, status indicator and
keystrokes.
1. Alarm type indicators: relevant indicator
is on when alarm (FIRE, GAS, PANIC,
BURG, AC, TEL, BAT, ANTI-TAMPER,
etc) happens. Intruder alarm includes
entry/exit zone, active zone and
perimeter zone.
2. Display range:
Display real-time clock normally
Display input digits when setting.
Display corresponding alarm zone number
when the system alarms.
3. Power indicator: It will keep on after
keypad is switched on.
●
●
●
5.13 AC power connection
●
Check line connection again, ensuring all lines are connected correctly.
●
Switch on AC power, power indicator on the keypad will be on; buzzer will beep twice; back light of the keypad,
alarm indicator and second clock indicator flash once; nixie tube display show '8888'. Keypad begins to initialize
and then buzzer continuously beeps until nixie tube shows real-time again and second clock indicator flashes
once a second. Then the system works normally.
7
14
9.3.11 Buzzer chirp time setting Enter: 29 XX
Operations: (PROG
→
user password
→
#)
→
29
→
XX
→
#
Parameters definition:
delay time is among 0~ 30 minutes
XX=00( alarm but without alert)
XX= 01 (1 minute)
XX= 02 (2 minutes)
XX =10 (10 minutes)
XX =20 (20 minutes)
XX =30 (30 minutes)
The factory setting is XX= 10(10 minutes)
Function:
Buzzer chirp time adjustment
9.3.12 Exit delay adjustment Enter: 30 XX
Operations: (PROG
→
user password
→
#)
→
30
→
XX
→
#
Parameters definition:
XX=00~30, indicating time, unit is 10 seconds, delay time is among 0~300 seconds.
XX=00( no delay)
XX=01(10 seconds)
XX=02( 20 seconds)
XX=10( 100 seconds)
XX=20( 200 seconds)
XX=30(300 seconds)
The factory setting is XX=10(100 seconds)
9.3.13 Entry delay adjustment Enter: 31 XX
Operations: (PROG
→
user password
→
#)
→
30
→
XX
→
#
Parameters setting:
XX=00~30, indicating time, unit is 10 seconds, delay time is among 0~300 seconds.
XX=00(no delay)
XX=01(10 seconds)
5.11 Telescopic antenna installation
●
When telephone line is lost in self- checking status, the control panel will alarm for telephone line lost. "Loss"
indicator will be on, and buzzer chirps twice in every two minutes until chirps 15 times(30minutes). When
telephone line is restored, "Loss" indicator will be off.
4. Status indicator: Keep on when the system is in arm away status; flash when the system in arm stay status and
keep off when the system in disarm status.
5. Back light: If any keystroke is pressed, back light is on, if no other keystroke is pressed in 30 seconds, back light
is off.
6. Keys: 4 function keystrokes: arm-away keystroke, arm-stay keystroke, disarm keystroke and program/panic
keystroke which has two functions, one is used to program, the other is used in emergent condition.
Number key (0~9), '
*
' keystroke and ' # ' keystroke: they are used in programming and arm/disarm operations. '
*
'
keystroke is used for canceling the last input operation and ' # ' keystroke is for confirmation.
The cabinet of the control panel should be installed telescopic
antenna for accepting wireless detector and remote controller.
(refer to the figure below)
Antenna
Antenna mounting hole
Anti-tamper switch position
Antenna connecting line
Nut
1
2
3
4
5
6
7
8
9
0
Duress
Burglay
Fire
Gas
Medical
Loss
Low
voltage
Others
power
status
STAY
AWAY
DISARM
PROG
status indicator
power indicator
keystrokes
display range
Alarm
indicators
5.12 Relay output terminal
●
The biggest load capacity of relay
terminal (KG1,KG2) is 120V /3A,
24VDC/3A
STAY
AWAY
DISARM
PROG
Functions:
The control panel supports 4+1ADMECO and Contact ID communication.
9.3.10 Relay output type setting Enter: 28 X
Operations: (PROG
→
user password
→
#)
→
28
→
X
→
#
Parameters definition:
X=1,alarm output,X=2,fire output,X=3,arm output
The factory setting is X=2 ,fire output
Functions:
Relay output type can be set as required. If alarm output is set, the relay will be closed while alarming
and KG1 and KG2 are conducted. If fire alarm output is set, the relay will be closed only in fire zone. If armed