Functions:
Add or reduce wireless detectors as required.
For example:
Cancel NO.23 detector in wireless zones, press: (PROG
→
user password
→
#)
→
62
→
23
→
#.
4
17
9.3.23 Wireless remote controller removing Enter: 64 X
Operations: (PROG
→
user password
→
#)
→
64
→
X
→
#.
Parameters definition:
X=1~5, number of wireless remote controller.
Functions:
The system can enroll 5 wireless remote controllers at most to do operations of arm away/stay, disarm
and panic, cancel wireless remote controller as required. After canceling some remote controller they will have no
9.3.24 Zone bypass Enter: 65 XX
Operations: (PROG
→
user password
→
#)
→
65
→
XX
→
#.
Parameters definition:
XX means zone bypass number.
X=01~16 (16 wired zones, and 09~ 16 are expanded wired zones);
XX=17(remote controller and panic key in the keypad.)
XX=21~28 (8 wireless zones);
XX=30(control panel with anti-tamper function)
XX=31~34(keypad controller with anti-tamper function)
XX=41~48 (4 keypads have 8 wired zones);
XX=51~54 (4 keypads loss)
Bypass for all wired zones in factory default setting, no bypass for other zones.
Functions:
User needs to close some zone temporarily, then the zone can be activated freely without alarm. At this
9.3.25 Zone bypass canceling Enter: 66 XX
5.5.1 Concealed installation
●
Keypad wiring board terminal
V_KEY:
Power input terminal on the keypad, offered overload protection by fast-below fuse
V_KEY (1A) of the master controller.
GND:
Power ground.
A&B:
Data line for communication between keypad and the master controller.
V_AUX:
Power input terminal of two wire zones extended by keypad, connecting to anode of the
power supply.
V_KEY
B
A
GND
Wiring
port
V-AUX
Z1
GND
GND Z2
GND
W
ir
in
g
b
o
a
rd
fi
g
u
re
5.5. Keypad installation
The keypad provides two modes of installation for various surroundings: concealed installation (fixed on the wall by
86 box, wiring board and bracket) and open installation (fixed on the wall by screws).
B
ra
c
k
e
t i
n
s
ta
lla
tio
n
fi
g
u
re
120
8
0
1
0
.6
3
3
20
3
0
Bracket figure (Unit:mm)
Wall
Bracket
Gang
socket
Tamper
switch
Fixed card
hole
fixed iron stand
Fixed grab
Screw fixed
leg
Screw hole
Screw hole
Battery
12V 7.0Ah
sealed lead-acid
rechargeable battery
9.3.22 Wireless remote controller code learn Enter: 63 X
Operations: (PROG
→
user password
→
#)
→
63
→
X
→
#.
Parameters definition:
X=1~5, number of wireless remote controller.
Functions:
The system can enroll 5 wireless remote controllers at most to do operations of arm away/stay, disarm
and panic, add wireless remote controller as required. After inputting command, press any key of wireless remote
●
Standby power is offered overload protection by fast-blow fuse BATTERY(1A). If the fuse
opens, remove the short or overload condition, and then replace the fuse before restoring
power. Do not substitute a higher rated fuse.
●
The system checks automatically the state of battery. If disconnect to standby power or
voltage of standby power , the control panel will take operation of low-voltage, "Low-
voltage" indicator on keypad will be on, and buzzer will chirp twice in every two minutes
until chirps 15 times(30minutes).
Operations: (PROG
→
user password
→
#)
→
66
→
XX
→
#.
Parameters definition::
XX means canceling bypassed zone number.
XX=01~16 (16 wired zones, and 09~ 16 are expanded wired zones);
XX=17(remote controller and panic key in the keypad
XX=21~28 (8 wireless zones);
XX=30(control panel with anti-tamper function)
XX=31~34(keypad controller with anti-tamper function)
XX=41~48 (4 keypads have 8 wired zones);
XX=51~54 (4 keypads loss)