5
●
Wiring terminal on keypad plate
V_KEY:
Power input terminal on the keypad, offered overload protection by fast-below fuse V_KEY (1A) of the
master controller.
GND:
Power ground.
A&B:
Data line for communication between keypad and the master controller.
V_AUX:
Power input terminal of two wire zones extended by keypad, connecting to anode of the power supply.
Z1&Z2:
Two wire zones extended by keypad.
●
Connection between the wiring terminal of keypad and the control panel : Connect V_KEY, B, A and GND port in
the control panel to those in the keypad wiring board respectively, and fix them by screws. See correspondent
16
9.3.20 Code for wireless zone Enter: 61 XX
Operations: (PROG
→
user password
→
#)
→
61
→
XX
→
#.
Parameters definition:
X=21~28, indicating zone number of wireless detector .
Functions:
Add or reduce wireless detectors as required.
For example:
Enroll NO.23 detector in wireless zones, press:
(PROG
→
user password
→
#)
→
61
→
23
→
#.
Note:
After inputting command, user has to activate a wireless detector in 1 minute, the code will fail. Moreover,
●
Connection between the wiring board of keypad and the control panel: Connect V_KEY, B,A and GND port in the
control panel to those in the keypad wiring board respectively, and fix them by screws.
●
Advised to use twisted pair line (RVVP4 1.0). The distance between keypad and the control panel can reach
120m.
●
Connection between wiring board and keypad : Insert one end of connecting wire into the interface slot at the
back of keypad, and the other into the interface port of wiring board.
●
Keypad fixation: Press spring of anti-tamper switch in the spring hole, then hang the keypad on installed fixed
iron stand. Ensure the spring is pressed tightly by the fixed iron stand.
Rear cover of keypad sketch
Locating hole
Terminal slot
Anti-tamper switch spring hole
Card slot
Buzzer hole
Dial switch hole
Interface slot
Card slot
Outlet slot
5.5.2 Surface installation
●
Connect keypad to the control panel and fix the keypad on the wall through the four locating holes at the rear
cover of keypad..
Keypad PCB wirin g sketch
CPU
V_KEY GND
Z2 GND Z1
B
A
V_AUX
Buzzer
Wiring slot
Wiring terminal
Dial switch
9.3.19 Zone type setting Enter: 40 XX Y
Operations: (PROG
→
user password
→
#)
→
40
→
XX
→
Y
→
#.
Parameters definition:
XX means wireless zone number.
X=01~16(16 wired zones, and 09~16 are expanded wired zones); X=21~28(8 wireless zones);
X=41~48 (4 keypads have 8 wired zones);
Y means zone type: type code Y=1/2/3/4/5/6/7/8
Y=1, entry/exit zone;
Y=2, active zone;
Y=3, perimeter zone;
Y=4, panic zone;
Y=5, fire zone;
Y=6, gas zone;
Y=7, anti-tamper zone;
Y=8, duress zone.
In factory default setting, zone types of 8 zones ahead are numbered correspondently. Zone 1 is type 1(entry/exit
zone), zone 2 is type 2(active zone)...The expanded 8 wired zones and keypad wired zones belong to type
3(perimeter zone), and all wireless zones belong to type 4(panic zone) in the factory default.
Functions:
Modify zone types.
For example:
Set wireless zone 21 as gas zone, wire zone 3 as fire zone, press (PROG
→
user password
→
#)
→
40
→
21
→
6
→
#
→
40
→
03
→
5
→
#
Note:
When the system is in arm- away status, all zones are valid; when the system is in arm- stay status, active
zone is invalid, but other zones are still in valid ; when the system is in disarm status, fire zone, gas zone, panic
Press(PROG
→
user password
→
#)
→
36
→
1
→
0800
→
#
→
36
→
2
→
2200
→
#
Note:
Before performing the functions above , please set 'Timed auto-arm/auto-disarm selection' first, refer to
9.3.7. Auto-arm/disarm time must be different .They can
’
t be operated at the same time.
9.3.21 Wireless zone detector canceling Enter: 62 XX
Operations: (PROG
→
user password
→
#)
→
62
→
XX
→
#.
Parameters definition:
X=21~28, indicating zone number of wireless detector .