9.3.8 Telephone line checking on/off option Enter : 26X
Operations: (PROG
→
user password
→
#)
→
26
→
X
→
#
Operations definition:
X=1, on
X=0, off
The factory setting is X=1,on
Functions:
When the control panel is not connected with telephone, use this command to forbid checking the
8
7. Alarm mode
When the telephone alarms, sounds will be sent out in 5 seconds until the telephone is hung-up. If there is no
sound or the user is unwilling to wait for a long period during off-hook, the user can press any key (key '5'
recommended), the control panel will send out voice immediately. Broadcast the user's address first, then the
alarm type. After all of the alarm types have been broadcasted, wait five seconds then it will be broadcasted
circularly .If user not press any keys to operate, the voice of alarm type will broadcast again for five times, then the
telephone will be hung-up automatically. The user can press keys to operate until the voice has been broadcasted
for five times. See the specific operation in "Remote phone operations". Before broadcasting, keys operation can
not be regarded as remote telephone command.
13
9.3.4 Operation password modification Enter:22 XXXX
Operations: (PROG
→
user password
→
#)
→
22
→
XXXX
→
#
Parameter definition:
XXXX is 4 digits operation password. The factory setting is 1234.
Functions:
User can modify operation password which can only be used to disarm except programming.
9.3.5 Ringing attempts adjustment Enter:23 X
Operations: (PROG
→
user password
→
#)
→
23
→
X
→
#
Parameters definition:
X means ringing attempts=1~ 9 times(X=0 indicating no phone remote control and no
automatically receiving the telephone) The factory setting is 6.
Functions:
The system is able to operate in remote place. When user in other place dials phone connected to the
master control panel, the system will lift the telephone automatically. User can input password to arm or disarm.
Note:
If user telephone uses the same telephone line with the master controller, set ringing attempts as many as
possible to avoid clashing between telephone normal operation and system remote operation. After setting ringing
attempts, the system begins to accept user remote operation.
9.3.6 Bell on/off setting Enter: 24 X
Operations: (PROG
→
user password
→
#)
→
24
→
X
→
#
Parameters definition:
X=1, on; X=0, off. The factory setting is X=1 (on).
Functions:
User can choose using bell alarm or not. Setting the bell, it will be on when the system alarms;
otherwise only buzzer on keypad chirps.
9.3.7 Timed auto-arm/auto-disarm option Enter: 25 X
Operations: (PROG
→
user password
→
#)
→
25
→
X
→
#
Parameters definition:
X=1: valid (Timed arm/disarm allowed).
X=0: invalid (Timed arm/disarm not allowed)
The factory setting is X=0 (Timed arm/disarm not allowed)
Functions:
The system can be set auto-arm or auto-disarm in certain moment as required. After setting the
8. Zone type and definitions of zone number
8.1 Zone type
Zone type
Disarm
Ineffective
Ineffective
Ineffective
Effective
Effective
Effective
Effective
Effective
Arm
away
Effective
Effective
Effective
Effective
Effective
Effective
Effective
Effective
Arm
stay
Effective
Ineffective
Effective
Effective
Effective
Effective
Effective
Effective
Exit
delay
Yes
Yes
No
No
No
No
No
No
Entry
delay
Yes
Yes
No
No
No
No
No
No
Acousto
-optic alarm
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Installation
position
or detector
Gate
Indoor
Veranda window
Panic key
Fire probe
Gas probe
Anti-tamper device
Duress key
Type
number
01
02
03
04
05
06
07
08
Entry/Exit zone
Active zone
Perimeter zone
Panic zone
Fire zone
Gas zone
Tamper zone
Duress zone
Alarm modes
Alarm types
protection
zones
Alarm
indicator
Keypad
buzzer
/
/
/
Dial to
alarm
Voice
alarm
Bell
Fire alarm
Gas alarm
Panic alarm
Burglary alarm
Duress alarm
Anti-tamper
Phone line
loss
AC power failure
DC power low-voltage
Fire zone
Gas zone
Panic zone
Perimeter zone
Active zone
Entry/Exit zone
Duress zone
Tamper zone
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
On
On
On
On
No
On
On
On
On
Chirp
(time adjustable)
Chirp
(time adjustable)
Chirp
(time adjustable)
Chirp
(time adjustable)
Muted
Chirp
(time adjustable)
Chirp once in
every two minutes
Chirp for 15
times all
Chirp
(time adjustable)
Chirp
(time adjustable)
Chirp
(time adjustable)
Chirp
(time adjustable)
Muted
Chirp
(time adjustable)
Muted
Muted
Muted
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
9.3.9 Agreement selection Enter: 27X
Operations: (Program
→
user password
→
#)
→
27
→
X
→
#
Parameters definition:
X=1
:
4+1 Agreement, X
=
0
:
ContactID Agreement,
Содержание LHD6000