LONGHORN LHD6000 Скачать руководство пользователя страница 1

INSTALLATION 

MANUAL

L H D 6 0 0 0

Manufacturer: Shenzhen Longhorn Technology Co., Ltd.
Add: Longhorn Hi-Tech Estate, TongFuyu Industrial Avenue, 

Longhua, Shenzhen G. D. China

Post number: 518109
Tel: 800 830 8196
Fax: +86-755-28140429

E-mail: [email protected]

Web address: http://www.long-horn.com

Содержание LHD6000

Страница 1: ...er Shenzhen Longhorn Technology Co Ltd Add Longhorn Hi Tech Estate TongFuyu Industrial Avenue Longhua Shenzhen G D China Post number 518109 Tel 800 830 8196 Fax 86 755 28140429 E mail service long horn com Web address http www long horn com ...

Страница 2: ...INSTALLATION MANUAL ...

Страница 3: ...acked in a box as followed Open the box and check it carefully If finding deficiency please fetch the provider in time Note There are two anti tamper switches of control panel twenty four EOL resistances 2 2k two keys for cabinet of control panel telephone line telescopic antenna keypad anti tamper switch spring screw expansion pipe and keypad fixed iron stand connecting line installation frame ke...

Страница 4: ...5mAh Potential reasons Solutions Types of fault Code learn unsuccessful Different detectors use the same code learn The different carrier frequency of the detector and the control panel The detector does not work normally Cancel this zone check the code learn again make sure the detector code learn has not been used Change the detector and try again Confirm carrier frequency of the detector Cancel...

Страница 5: ...Weekly testing is required to ensure proper operation of the system 14 Troubleshooting The controller plug is not inserted in DC socket or it is not connected well Check the connection of the plug or replace the socket Check whether keypad is wired incorrectly or not and wire Keypad is wired incorrectly Telephone can not work normally as the system is connected into telephone network Few ringing a...

Страница 6: ...ATION OF USER ARM DISARM Number Operation of using keypad without password such as arm away disarm and arm stay User password to arm disarm by using keypad or remote telephone Operation code of Arm disarm by using keypad or remote telephone Remote controller arm disarm Alarm for disarm arm operation by using telephone numbers from 2 to 6 Using duress code to disarm press 98 to send a disarm inform...

Страница 7: ...to alarm user can press 3 to disarm and then press 1 to arm after hearing alarm voice 11 3 Telephone arm stay After hanging up the system press user password 2 to arm When emergencies happen user has to disarm first and then arm the system again For example if user password is 1234 press 12342 When the master controller dials to alarm user can press 3 2 to arm after hearing sound 11 4 Telephone fi...

Страница 8: ...ll in armed state 24 hour zone No matter armed or disarmed it is in effective detecting status It is usually used in fire alarm plunder alarm and other emergent alarm which can be cancelled only by password holder 19 10 Wireless remote controller operation Wireless remote controller have 4 keys which can achieve operations of arm away stay disarm and panic alarm without user password Press keys on...

Страница 9: ...ng Functions Connect a horn to the control panel play 8 alarm type records and user address record The recorder 9 3 28 Event record reading Enter 80 XX Operations PROG user password 80 XX Parameters definition XX 01 40 event records Functions The system stores 40 event records which can be inquired by user any time The system records alarm in zones but no fault alarm for AC power loss low battery ...

Страница 10: ... GND Z2 GND Wiring board figure 5 5 Keypad installation The keypad provides two modes of installation for various surroundings concealed installation fixed on the wall by 86 box wiring board and bracket and open installation fixed on the wall by screws Bracket installation figure 120 80 10 6 33 20 30 Bracket figure Unit mm Wall Bracket Gang socket Tamper switch Fixed card hole fixed iron stand Fix...

Страница 11: ...sketch Locating hole Terminal slot Anti tamper switch spring hole Card slot Buzzer hole Dial switch hole Interface slot Card slot Outlet slot 5 5 2 Surface installation Connect keypad to the control panel and fix the keypad on the wall through the four locating holes at the rear cover of keypad Keypad PCB wiring sketch CPU V_KEYGND Z2 GND Z1 B A V_AUX Buzzer Wiring slot Wiring terminal Dial switch...

Страница 12: ...re keypads to avoid address clash It can be reached by adjusting address dial up switch on keypad back See the table below Note Dial up switch ON terminal is ON another terminal is OFF 1 OFF OFF ON ON 2 ID OFF ON OFF ON 1 NO1 keypad 2 NO2 keypad 3 NO3 keypad 4 NO4 keypad 15 9 3 15 Date setting Enter 33 XXXX Operations PROG user password 33 XXXX Parameters definition XXXX is for date setting XXXX m...

Страница 13: ...s XX 00 no delay XX 01 10 seconds 5 11 Telescopic antenna installation When telephone line is lost in self checking status the control panel will alarm for telephone line lost Loss indicator will be on and buzzer chirps twice in every two minutes until chirps 15 times 30minutes When telephone line is restored Loss indicator will be off 4 Status indicator Keep on when the system is in arm away stat...

Страница 14: ...ts the system begins to accept user remote operation 9 3 6 Bell on off setting Enter 24 X Operations PROG user password 24 X Parameters definition X 1 on X 0 off The factory setting is X 1 on Functions User can choose using bell alarm or not Setting the bell it will be on when the system alarms otherwise only buzzer on keypad chirps 9 3 7 Timed auto arm auto disarm option Enter 25 X Operations PRO...

Страница 15: ...G user password 11 XY Y Bracket means in programming status it is not necessary to input PROG user password enter command status directly Parameters setting X 1 6 indicates 1 6 groups telephone 1 is alarm number of the alarm center 2 6 are personal phone numbers Y Y indicates phone number needed to dial 1 15 digits phone number is null in factory setting Functions The system can be set 6 groups of...

Страница 16: ...faultsvaluesrestoration Keypadlogout 36 X Y 40 X Y 61 X 62 X 63 X 64 X 65 X 66 X 70 0 71 X 80 X 910 920 930 940 950 960 990 X 1 3 NO Xauto disarmmoment Y hourminute 4digits X 01 16 16wirezonesand 09 16areextendedwire zones X 21 28 8wireless zones X 41 48 4keypads have8wirezones TypecodeY 1 8 X 21 28 NO Xdetectorin wirelesszone X 21 28 NO Xdetectorin wirelesszone X 1 5 NO Xwirelessremote controller...

Отзывы: