APPLICATION AND VALIDATION PROCESS
EN
Engine below sea level with airvent valve installation scheme
If sea water outlet is at height of less than 200 mm from the
water line, fit an airvent system.
During the installation operations, the following instructions must be observed:
Compliance with the maximum inclinations permitted (owner manual)
8.2 Prescriptions to be respected
Exhaust line with muffler and terminal siphon installation scheme
If the exhaust line is ascending and the sea water exit from
the engine is under the waterline, install a muffler and a
non-return siphon.
Muffler must hold a large volume of water included between
the muffler and the exhaust exit.
ED0053032450