background image

LOGICLINK - MANUAL // PAGE 6

2  SAFETY

2.1  TARGET AUDIENCE

This Operating Manual is intended for Skilled Persons only. Refer to

 

Chapter 2.8 Skilled Persons on page 9 to 

ensure that personnel meet all requirements. 

2.2  GENERAL SAFETY REGULATIONS

In general, the following safety regulations and obligations apply when handling the product:

•  Do not operate the product unless it is in a clean and perfect condition
•  Do not remove, change, bridge, or bypass any protection, safety, or monitoring equipment
•  Do not convert or modify any components without written approval from LOGICDATA
•  In the event of malfunction or damage, faulty components must be replaced immediately
•  Unauthorized repairs are prohibited
•  Do not attempt to replace hardware unless the product is in a de-energized state
•  Only Skilled Persons are allowed to work with the LOGIClink
•  Ensure that national worker protection conditions and national safety and accident prevention 

regulations are observed during operation of the system

2.3  INTENDED USE

The LOGIClink is a range of Connectivity Hubs for Height-Adjustable Table systems. There are three versions 
of the LOGIClink: Corporate, Personal Standard, and Personal Lite. The products are installed by Resellers 
into Height-Adjustable Table systems. They are used to control Height-Adjustable Table systems via a Control 
Box or via the DYNAMIC MOTION system. Products are intended for indoor use only. Products may only 
be installed in compatible Height-Adjustable Tables and with LOGICDATA-approved accessories. Contact 
LOGICDATA for further details. Use beyond or outside the intended use will void the product’s warranty. 

2.4  REASONABLY FORESEEABLE MISUSE

Usage outside of the intended use may lead to minor injury, serious injury, or even death. Reasonably fore-
seeable misuse of the LOGIClink includes, but is not limited to:

•  Connecting unauthorized parts to the product. If you are unsure as to whether a part can be used 

with the LOGIClink, contact LOGICDATA for further information

•  Connecting unauthorized software to the product. If you are unsure as to whether a software can 

be used with LOGIClink, contact LOGICDATA for further information

•  Using the system as a climbing or lifting aid for people or animals
•  Overloading the Table System

Содержание LOGIC OFFICE Series

Страница 1: ...MANUAL Document Version 2 0 April 2019 LOGIClink Valid for LOGIClink Corporate LOGIClink Personal Standard LOGIClink Personal Lite Motion Work App...

Страница 2: ...0 April 2019 This document was originally published in English LOGICDATA Electronic Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 51 98 0 Fax 43 0 3462 51...

Страница 3: ...5 Explanation of symbols and signal words 7 2 6 Liability 7 2 7 Residual risks 8 2 8 Skilled Persons 9 2 9 Notes for Resellers 9 3 Scope of delivery 10 4 Unpackaging 10 5 Products 11 5 1 Key Product...

Страница 4: ...onnecting the LOGIClink 22 7 5 3 Next Steps 22 7 6 Marking the NFC Reading Area 23 8 Operation Manual 24 8 1 Adjusting the Table Top Height 24 8 2 Restart 25 8 3 Factory Reset 25 9 Operation via the A...

Страница 5: ...After purchase and full payment of the product all text and images in Chapter 2 Safety may be used free of charge by the customer for 10 years after delivery They should be used to prepare end user d...

Страница 6: ...range of Connectivity Hubs for Height Adjustable Table systems There are three versions of the LOGIClink Corporate Personal Standard and Personal Lite The products are installed by Resellers into Hei...

Страница 7: ...ce Protection Class III Protection Class III devices may only be connected to SELV or PELV power sources INFO Indicates important tips for handling the product 2 6 LIABILITY LOGICDATA products comply...

Страница 8: ...on heated surfaces Check the housing and Cables of the LOGIClink for visible damage Do not install or operate damaged products WARNING Risk of death or serious injury in explosive atmospheres Operati...

Страница 9: ...ty and product safety Resellers should provide end users with an Operating Manual in their native EU official language INFO The Charter of the French Language La charte de la langue fran aise or Bill...

Страница 10: ...r ESD handling during unpackaging Damage that can be attributed to electrostatic discharge will void warranty claims Always wear an anti static wristband To unpackage the product 1 Remove all componen...

Страница 11: ...ccompanying data sheet to check ensure that you have received the correct variant 5 1 KEY PRODUCT FEATURES 1 NFC Area LOGIClink Corporate and Personal Standard Only 2 Wi Fi Communication Module LOGICl...

Страница 12: ...below is an example LOGIClink Personal Standard The design of the shutter depends on the configuration of the LOGIClink you have ordered The outer dimensions of the LOGIClink are the same for all vari...

Страница 13: ...LOGICLINK MANUAL PAGE 13 5 3 DRILLING TEMPLATE Fig 3 Drilling Template LOGIClink Front Edge Side Edge 1 593 40 45 mm 4 409 112 0 mm 3 425 87 0 mm...

Страница 14: ...of minor or moderate injury through tripping During assembly and operation poorly routed Cables may become a trip hazard Tripping over Cables may lead to minor or moderate injury Ensure that Cables a...

Страница 15: ...e that the Signal LEDs can be seen from the front of the table INFO LOGICDATA recommends placing the LOGIClink roughly 70 cm from the user s normal sitting position 1 Mark the position of the drilling...

Страница 16: ...the user s right hand side turn the sensor towards R If the LOGIClink will be on the user s left hand side turn the sensor towards L Fig 5 Aligning the Presence Sensor 6 3 3 COMPLETING ASSEMBLY After...

Страница 17: ...ontact LOGICDATA before connecting the LOGIClink in order to confirm compatibili ty Failure to comply is classified as misuse and will void warranty claims The following products are compatible with L...

Страница 18: ...system setup if one or more of the following conditions apply You will connect an additional Handset to the LOGIClink You will connect the LOGIClink to a COMPACT e or SMART e Control Box was produced...

Страница 19: ...to minor or moderate injury through electric shocks Do not connect the Control Box to the Power Unit before the LOGIClink has been safely connected 1 Insert the LOG CBL LOGICLINK CB STANDARD Cable int...

Страница 20: ...does not supply this accessory and cannot provide guarantees regarding quality safety or performance 7 4 2 CONNECTING THE LOGICLINK CAUTION Risk of minor or moderate injury through electric shocks Co...

Страница 21: ...GIClink is connected assembly differs depending on the version of LOGIClink you have in stalled LOGIClink Corporate and Personal Standard Go to Chapter 7 6 Marking the NFC Reading Area All other varia...

Страница 22: ...ables while the DYNAMIC MOTION system is connected to the Power Unit may lead to minor or moderate injury through electric shocks Do not connect the DYNAMIC MOTION system to the Power Unit before the...

Страница 23: ...chapter 1 Locate the NFC Reading Area on the table top The Reading Area should be a 60 x 6o mm square directly over the LOGIClink 10 mm from the back edge Fig 7 2 Ensure the Reading Area is positioned...

Страница 24: ...LOGICDATA Control Boxes and the DYNAMIC MOTION system Before using a Control Box connected Table System you must also read the Operating Manual for the installed Control Box including all relevant sa...

Страница 25: ...e System from the Mains by removing the plug 2 Press and hold the UP and DOWN Keys 3 While holding the UP and DOWN Keys reconnect the Table System to the Mains The LEDs will flash LOGIClink Corporate...

Страница 26: ...e from the Google Play Store Android and the App Store iOS 9 2 PAIRING SMART DEVICES WITH LOGICLINK CAUTION Risk of minor or moderate injury through uncontrolled movement It is possible that more than...

Страница 27: ...the screen to begin pairing Tap Scan and Connect to find your LOGIClink Select the correct LOGIClink from the list of available devices When prompted tap Pair and Connect to pair with LOGIClink Enter...

Страница 28: ...ects are kept away from the edge of the table Do not leave unnecessary objects on the table during movement 9 3 1 ADJUSTING THE TABLE TOP HEIGHT CAUTION Risk of minor or moderate injury through crushi...

Страница 29: ...or Standing to save the position The Memory Position has been saved Fig 10 Saving a Memory Position 9 3 3 ADJUSTING THE TABLE TOP TO A SAVED MEMORY POSITION This function allows you to move the Taple...

Страница 30: ...ctivated auto movement function If you activate this function the grading of the safety functions according to EN ISO 13849 1 PL b Category B are no longer valid as the legal requirements in the stand...

Страница 31: ...uthorized spare or accessory parts may lead to death or serious injury through electric shocks and other hazards Only use accessory parts produced or approved by LOGICDATA Only use replacement parts p...

Страница 32: ...ftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 5198 0 Fax 43 0 3462 5198 1030 Email office at logicdata net Internet http www logicdata net LOGICDATA North America Inc Broadmoor Ave SE Suite...

Отзывы: