background image

LOGICLINK - MANUAL // PAGE 22

7.5  CONNECTION: DYNAMIC MOTION SYSTEM 

OPTION

7.5.1  REQUIRED COMPONENTS

1

LOGIClink

2

DYNAMIC MOTION system-compatible Power Hub (e.g. DMP240)

3

Micro-USB Cable (Optional - Supplied by Reseller)

4

LOGIClink-DM system Cable (

DMC-LL-y-1800

)

INFO

The 

DMC-LL-y-1800

 Cable has 2 connectors:

• 4-pin Mini-Fit (plugs into the Power Hub)

• 10-pin Mini-Fit (plugs into the LOGIClink)

INFO

The Micro-USB Cable is used to connect LOGIClink to your PC or Mac. When connected 

to the DYNAMIC MOTION system, it can also be used as a parameterization tool. It is 

not required during standard operation of the table system. For further advice on soft-

ware options, contact LOGICDATA. 

7.5.2  CONNECTING THE LOGICLINK

CAUTION

Risk of minor or moderate injury through electric shocks

Connecting Cables while the DYNAMIC MOTION system is connected to the Power Unit 

may lead to minor or moderate injury through electric shocks. 

•  Do not connect the DYNAMIC MOTION system to the Power Unit before the 

LOGIClink has been safely connected. 

1.  Insert the 

DMC-LL-y-1800 

Cable into the LOGIClink using the 10-pin Mini-Fit connector.

2.  Lay the Cable along the underside of the table top, making sure it is secured. 
3.  Connect the 4-Pin Mini-Fit connector to the Power Hub.
4.  (Optional) connect the LOGIClink to your PC or Mac using the Micro-USB cable.
5.  Connect the DYNAMIC MOTION system to the mains. Consult the DYNAMIC MOTION system 

Manual for assembly and safety advice.

7.5.3  NEXT STEPS

After the LOGIClink is connected to the DYNAMIC MOTION system, assembly differs depending on the ver-
sion of the LOGIClink you have installed. 

LOGIClink Corporate and Personal Standard: Go to Chapter 7.6, Marking the NFC Reading Area.
All other variants:  Assembly is now complete. Go to Chapter 8, Operation. 

Содержание LOGIC OFFICE Series

Страница 1: ...MANUAL Document Version 2 0 April 2019 LOGIClink Valid for LOGIClink Corporate LOGIClink Personal Standard LOGIClink Personal Lite Motion Work App...

Страница 2: ...0 April 2019 This document was originally published in English LOGICDATA Electronic Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 51 98 0 Fax 43 0 3462 51...

Страница 3: ...5 Explanation of symbols and signal words 7 2 6 Liability 7 2 7 Residual risks 8 2 8 Skilled Persons 9 2 9 Notes for Resellers 9 3 Scope of delivery 10 4 Unpackaging 10 5 Products 11 5 1 Key Product...

Страница 4: ...onnecting the LOGIClink 22 7 5 3 Next Steps 22 7 6 Marking the NFC Reading Area 23 8 Operation Manual 24 8 1 Adjusting the Table Top Height 24 8 2 Restart 25 8 3 Factory Reset 25 9 Operation via the A...

Страница 5: ...After purchase and full payment of the product all text and images in Chapter 2 Safety may be used free of charge by the customer for 10 years after delivery They should be used to prepare end user d...

Страница 6: ...range of Connectivity Hubs for Height Adjustable Table systems There are three versions of the LOGIClink Corporate Personal Standard and Personal Lite The products are installed by Resellers into Hei...

Страница 7: ...ce Protection Class III Protection Class III devices may only be connected to SELV or PELV power sources INFO Indicates important tips for handling the product 2 6 LIABILITY LOGICDATA products comply...

Страница 8: ...on heated surfaces Check the housing and Cables of the LOGIClink for visible damage Do not install or operate damaged products WARNING Risk of death or serious injury in explosive atmospheres Operati...

Страница 9: ...ty and product safety Resellers should provide end users with an Operating Manual in their native EU official language INFO The Charter of the French Language La charte de la langue fran aise or Bill...

Страница 10: ...r ESD handling during unpackaging Damage that can be attributed to electrostatic discharge will void warranty claims Always wear an anti static wristband To unpackage the product 1 Remove all componen...

Страница 11: ...ccompanying data sheet to check ensure that you have received the correct variant 5 1 KEY PRODUCT FEATURES 1 NFC Area LOGIClink Corporate and Personal Standard Only 2 Wi Fi Communication Module LOGICl...

Страница 12: ...below is an example LOGIClink Personal Standard The design of the shutter depends on the configuration of the LOGIClink you have ordered The outer dimensions of the LOGIClink are the same for all vari...

Страница 13: ...LOGICLINK MANUAL PAGE 13 5 3 DRILLING TEMPLATE Fig 3 Drilling Template LOGIClink Front Edge Side Edge 1 593 40 45 mm 4 409 112 0 mm 3 425 87 0 mm...

Страница 14: ...of minor or moderate injury through tripping During assembly and operation poorly routed Cables may become a trip hazard Tripping over Cables may lead to minor or moderate injury Ensure that Cables a...

Страница 15: ...e that the Signal LEDs can be seen from the front of the table INFO LOGICDATA recommends placing the LOGIClink roughly 70 cm from the user s normal sitting position 1 Mark the position of the drilling...

Страница 16: ...the user s right hand side turn the sensor towards R If the LOGIClink will be on the user s left hand side turn the sensor towards L Fig 5 Aligning the Presence Sensor 6 3 3 COMPLETING ASSEMBLY After...

Страница 17: ...ontact LOGICDATA before connecting the LOGIClink in order to confirm compatibili ty Failure to comply is classified as misuse and will void warranty claims The following products are compatible with L...

Страница 18: ...system setup if one or more of the following conditions apply You will connect an additional Handset to the LOGIClink You will connect the LOGIClink to a COMPACT e or SMART e Control Box was produced...

Страница 19: ...to minor or moderate injury through electric shocks Do not connect the Control Box to the Power Unit before the LOGIClink has been safely connected 1 Insert the LOG CBL LOGICLINK CB STANDARD Cable int...

Страница 20: ...does not supply this accessory and cannot provide guarantees regarding quality safety or performance 7 4 2 CONNECTING THE LOGICLINK CAUTION Risk of minor or moderate injury through electric shocks Co...

Страница 21: ...GIClink is connected assembly differs depending on the version of LOGIClink you have in stalled LOGIClink Corporate and Personal Standard Go to Chapter 7 6 Marking the NFC Reading Area All other varia...

Страница 22: ...ables while the DYNAMIC MOTION system is connected to the Power Unit may lead to minor or moderate injury through electric shocks Do not connect the DYNAMIC MOTION system to the Power Unit before the...

Страница 23: ...chapter 1 Locate the NFC Reading Area on the table top The Reading Area should be a 60 x 6o mm square directly over the LOGIClink 10 mm from the back edge Fig 7 2 Ensure the Reading Area is positioned...

Страница 24: ...LOGICDATA Control Boxes and the DYNAMIC MOTION system Before using a Control Box connected Table System you must also read the Operating Manual for the installed Control Box including all relevant sa...

Страница 25: ...e System from the Mains by removing the plug 2 Press and hold the UP and DOWN Keys 3 While holding the UP and DOWN Keys reconnect the Table System to the Mains The LEDs will flash LOGIClink Corporate...

Страница 26: ...e from the Google Play Store Android and the App Store iOS 9 2 PAIRING SMART DEVICES WITH LOGICLINK CAUTION Risk of minor or moderate injury through uncontrolled movement It is possible that more than...

Страница 27: ...the screen to begin pairing Tap Scan and Connect to find your LOGIClink Select the correct LOGIClink from the list of available devices When prompted tap Pair and Connect to pair with LOGIClink Enter...

Страница 28: ...ects are kept away from the edge of the table Do not leave unnecessary objects on the table during movement 9 3 1 ADJUSTING THE TABLE TOP HEIGHT CAUTION Risk of minor or moderate injury through crushi...

Страница 29: ...or Standing to save the position The Memory Position has been saved Fig 10 Saving a Memory Position 9 3 3 ADJUSTING THE TABLE TOP TO A SAVED MEMORY POSITION This function allows you to move the Taple...

Страница 30: ...ctivated auto movement function If you activate this function the grading of the safety functions according to EN ISO 13849 1 PL b Category B are no longer valid as the legal requirements in the stand...

Страница 31: ...uthorized spare or accessory parts may lead to death or serious injury through electric shocks and other hazards Only use accessory parts produced or approved by LOGICDATA Only use replacement parts p...

Страница 32: ...ftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 5198 0 Fax 43 0 3462 5198 1030 Email office at logicdata net Internet http www logicdata net LOGICDATA North America Inc Broadmoor Ave SE Suite...

Отзывы: