4
Observe general safety regulations for the handling of chemicals such as
Loctite
®
adhesives and sealants. Observe the manufacturer’s instructions as stated
in the Safety Data Sheet.
While under warranty, the unit may be repaired only by an authorized Loctite
service representative.
1.3
Unpacking and Inspection
Carefully unpack the Loctite
®
EQ RC50 Integrated Dispenser I-4.0 and examine the
items contained in the carton. Inspect the unit for any damage that might have
occurred in transit. If such damage has occurred, notify the carrier immediately.
Claims for damage must be made by the consignee to the carrier and should be
reported to the manufacturer.
1.4
Packing List
•
EQ RC50 Integrated Dispenser I-4.0 x 1
•
Equipment Manual x 1
•
Universal Power AC Adapter with Cord x 1
•
Reservoir Tank Fitting: ¼ inch NPT x ¼ Inch Tubing x 1
•
Bottle Holder x 1
•
¼” NPT to 6 mm inlet supply line
connector x 1
•
Anti-Bubbler Fitting and Tubing Kit x 1
•
Footswitch x 1
•
Bottle spacer disc x 1
1.5
Features
•
Two independent digital timing channels that provide control of 2
pneumatic outputs
•
Low level sensor alarm provides warning for adhesive bottle replacement
•
Touch screen User Interface (UI) with color display and ease of use
•
Two operating modes: Auto Timer and Continue mode.
•
Equipped with a 0 to 7 bar (0-100psi) digital pressure regulator
•
Integrated with I/O communication interface