31
8
Care and Maintenance
8.1 Care
-Occasionally the O-ring at the reservoir lid should be lubricated with the silicone
grease. This will prolong the life of the O-ring.
Notice:
Clean hands after application of grease to ensure surfaces to be
bonded are clean.
-Clean the sensor surface as required.
-Both the bottle surface and the sensor surface must be free of condensed moisture!
8.2 Cleaning
-Prior to extended idle times or when changing of the product type, clean the product
hose and the dispensing valve.
-Loosen reservoir locking knobs (7) and remove the reservoir lid (8).
-Clean product residue from the outside of the feedline hose.
-Remove the product bottle and insert a container with approx. 0.5 liter of cleaning
agent.
-Put on the reservoir lid (8) and uniformly tighten the reservoir locking knobs (7).
-Operate the dispenser continuously until dry air streams out of the dispensing valve
(see operating instructions for the dispensing valve).
-Remove the empty cleaning agent container.
8.3 Maintenance
-Check the reservoir knobs and the product feed line on the regular basis. If there is
any sign of cracks, replace them!
-Clean, dry, filtered air must be used. If it is not, the solenoids on the controller will
be fouled over time.
Notice:
If the required air quality is not achieved, install a Loctite® filter
regulator. In the US order a 5
m filter using Part Number 478603. In Europe or Asia,
order a 10
m filter using Part Number 88649. The unit requires no special care and
maintenance.