23
5.7 Adjusting the Level Sensor
Notice:
The level sensor is set in manufacturing and can be adjusted according to the type of
product used and the size of the bottle, and orientation of the basket with spacers if
required. If small bottles are used the supplied Bottle spacer disc can be placed in
the base of the reservoir to raise the height of the bottle to reduce the residual
adhesive in the bottle when low level is used.
Before adjusting the Level Sensor
•
Remove the plastic cap from the rear of the EQ RC50 Integrated Dispenser I-4.0.
•
Empty a bottle of the product you use.
•
Leave as much residue in the bottle as is required in
order to prevent air getting into the product feedline.
•
Insert the product bottle into the reservoir. For small
bottles use bottle holder. For 250ml product bottle, pay
attention to ensure the bottle is aligned with the level
sensor.
•
Check that the product bottle inserted into the bottle holder is pressed against the
level sensor. Only then the correct adjustment of the level sensor is possible.
Procedure to Adjust the Level Sensor:
•
Switch the power switch (1) ON.
•
Remove the metal screw from the level sensor.
•
With an electrician’s screwdriver, find the point at which
the sensor switches to the condition inactive. The LED is
“OFF”.
•
Check this adjustment with a full bottle and an empty
bottle again.
•
Refit the metal screw to the level sensor.
•
Put the plastic cap back.
Notice:
The correct adjustment is exactly the point when the sensor switches OFF.
Do not go beyond that point!
Содержание PULSE EQ RC50
Страница 1: ...1 PULSE EQ RC50 Integrated Dispenser IDH 2814024 Operating Manual ...
Страница 34: ...34 XS9 PLC Interface ...
Страница 35: ...35 ...
Страница 38: ...38 ...
Страница 39: ...39 ...
Страница 40: ...40 ...