10
-
Use flexible pneumatic hoses and Loctite supplied product feedlines to prevent
unnecessary loads on the fittings and to ensure compatibility.
-
Ensure all pneumatic and product fittings are tight.
-
No direct sunlight; no UV light.
-
No condensing humidity.
-
No splashing waters.
-
No high magnetic and intense electric field.
4.2 Connecting the Unit
-
Use only the cable and hose sets supplied.
-
Connect Air pressure supply to pneumatic connection (15).
-
Plug the AC power cord into Power inlet (12), which located in rear side of the EQ
RC50 Integrated Dispenser I-4.0.
-
For manual operation, plug the footswitch into the 9 pin D-sub connector marked
XS1, located on the rear panel of the EQ RC50 Integrated Dispenser I-4.0.
-
For automated control, connect external PLC output relay to pins one and nine of
XS1.
-
Insert feedline through the reservoir lid to the dimension shown below. Alternatively
use the reference line shown on the housing to set the feedline length. Cut the end
of the feedline at an angle as shown below.
-
Connect dispensing valve(s).