Type of malfunction
Possible causes
Correction
Troubleshooting
7
The digital display does not
light.
No change in the value on the
digital display.
No product, too little or too
much product.
The error message
(with beeping) blinks in the
digital display:
P
Pr
re
es
ss
s.
.
= Dispensing pressure.
0
0.
.8
83
3
[bar/psi]
= Example for the indication
of dispensing pressure.
N
NO
OK
K
= Not O.K.
Product drips.
– No power voltage present.
– Power switch
10
in position
O
(OFF).
– Power fuse
23
is defective.
– Power cord
19
is defective.
– Control unit is defective.
– No air pressure is present.
– Control unit is defective.
– Dispensing pressure is not set correctly.
– Pressure hose is not properly connected.
– Syringe
15
is not properly connected.
– Hose clamp
11
is pressed closed.
– Luer-Lock tip cap
17
is not removed.
– Dispensing needle
16
is clogged,
too small or too large.
– Control unit is defective.
– The unit was switched off and the
pressure regulator
9
is now adjusting to
the dispensing pressure setting. The
indicated dispensing pressure is
increased continuously.
– Pressure regulator
9
was unintentionally
changed by more than ±10 %.
– Dispensing pressure was set to a new
value of more than ±10 %.
– Leak in the system.
– Vacuum regulator
7
is set too low.
– Exhaust air silencer
22
is clogged.
●
Check the power voltage.
●
Switch power switch
10
to position
I
(ON).
●
Check/replace fuse
23
.
●
Replace power cord
19
.
●
Contact Henkel Service.
●
Check pneumatic supply.
●
Contact Henkel Service.
●
Adjust dispensing pressure setting.
●
Connect air pressure hose correctly.
●
Attach syringe
15
correctly
(Section 5.2.1).
●
Release hose clamp
11
.
●
Replace Luer-Lock tip cap
17
with a
dispensing needle
16
.
●
Replace dispensing needle
16
.
●
Contact Henkel Service.
●
Wait until the pressure regulator
9
has
adjusted the dispensing pressure.
The error message and beeping are
eliminated when the indicated dispensing
pressure is within -10 % of the stored
comparison value.
●
Adjust pressure regulator
9
until the error
message and beeping are eliminated.
●
Press button
to store the indicated
dispensing pressure as the new
comparison value for the automatic
pressure monitoring. This eliminates the
error message and beeping.
●
Check system for leakage.
●
Contact Henkel Service.
●
Turn the vacuum regulator
7
counter
clockwise until the dripping stops
(Section 5.2.1).
●
Replace the silencer.