22
Troubleshooting
7
Type of malfunction
Possible causes
Correction
LED in button
or
does
not light.
No start signal.
No reaction from the buttons.
CONT
START
– LED is defective.
– Button is defective.
– Control unit is defective.
– Plug on the socket XS1: Start
25
is loose.
– Foot Switch
20
is defect.
– Control unit is defective.
– Button is defective.
●
Contact Henkel Service.
When the button is operational (check by
means of the digital display), the unit can
be used until repaired by Henkel Service.
●
Contact Henkel Service.
●
Contact Henkel Service.
●
Switch the power switch
10
to the
position
O
(OFF).
Tighten the screws of the plug.
Switch the power switch
10
to the
position
I
(ON).
●
Replace the Foot Switch
20
.
To test (alternative), use button
.
●
Contact Henkel Service.
●
Contact Henkel Service.
START
Documentation
8
8.1
Pin Connections for Foot Switch Cable
1
2
2
1
S1
3
4
5
6
7
8
9
Foot Switch
Sub–D 9pol. male
PROVERTHA
Solder Pot Version
With Contacts Machined
male SDT 09 51 G3
Plastic Hood with Side
Screw Locks
Metalized Hood
17 09 OM 38T 001
Controller XS1
2x 0.25 qmm
length: 3 m
type: shield, flexi
approved: VDE, CA, UL