15
5.2
First Operation
5.2.1
Purging Air from the Syringe
☞
To avoid air bubbles during dispensing, the tip of the syringe must be purged of air.
●
Hold the syringe
15
over a container
since product will flow out!
●
Switch the power switch
10
to the position
I
(ON).
●
With the pressure regulator
9
, set the dispensing
pressure to 0.50 bar (approx. 7.00 psi). The
dispensing pressure set can be read from the
digital display.
●
Press button
to switch to
cont
inuous mode
(see Section 5.2.2.2).
●
Press and hold button
(or the
Foot Switch
20
) until the product flows free of
bubbles from the dispensing needle
16
.
●
Press button
to switch off
cont
inuous mode.
☞
If the product drips out of the dispensing needle
16
:
●
Turn the vacuum regulator
7
counter clockwise until the dripping stops.
Do not continue turning after the dripping has stopped. When air is sucked in,
the syringe must again be purged of air and curing of the product can occur!