If you have any questions concerning this bulletin, please contact Manitowoc Beverage Equipment’s Technical Service Department at (800) 367-4233
5031703
09/29/05 REV 1
Installation Instructions
FLAVOR MAGIC COVER EXCHANGE PROCEDURE
FIGURE 1
FIGURE 2
FIGURE 3
FIGURE 4
1. Disconnect power to ice drink dispenser.
2. Remove translite and lamps in work area.
3. Remove and discard vinyl lines from retainer in cover and
from valves. Clean up any syrup spills.
4. Disconnect ribbon connector on cover touchpad (A) and
LED from harness (B) connected to circuit board. Discon-
nect harness from circuit board and discard (C).
5. If chute bracket (D) present go to step 6. Loosen right chute
bracket (E) mounting screw and attach bracket chute (D).
CAUTION: DO NOT STRESS PLASTIC COMPONENTS
IN THIS AREA TO AVOID BREAKAGE.
6. Loosen screws (F) holding cover assembly to cover bracket
and cover bracket (G) to chute bracket (D). Remove and
discard cover assembly & cover bracket.
7. Tighten right rocking chute bracket screw (if applicable).
8. Route the four (4) vinyl lines extending from the back of the
cover pad assembly through the opening between the mer-
chandiser bottom and rocking chute.