background image

Rev. 090921

U / EN

User manual

NORDIC

Juice machine

Your retail dealer

...............................................................................

...............................................................................

Summary of Contents for NORDIC

Page 1: ...Rev 090921 U EN User manual NORDIC Juice machine Your retail dealer ...

Page 2: ... and chilled water The dispenser is connected to the water mains by a pressurised tube and to an electric wall socket by a power plug The water pressure is adjusted with the water regulator and the pressure is displayed on the manometer The water is chilled by the cooling block which in its turn is chilled by the air cooled compressor The water temperature is adjustable with a thermostat The mixin...

Page 3: ...s one for products with cells and one for products without cells Turn the adjustment screws according to the label on the ejector in order to increase or decrease the amount of concentrate 3 Dispenser description Nordic Picture description Water regulator with manometer The water regulator can be adjusted up to 6 bar The minimum pressure is 2 2 bar Note When adjusting the pressure dispense product...

Page 4: ...he push buttons on the front panel controls the water valves Use only one button at a time Cooling block The cooling block is a flow through block with three built in stainless steel coils The coils are for water refrigerant R134A and thermostat Transformer The transformer is a 230 24 V 32 VA The transformer supplies 24 V to the magnetic valves ...

Page 5: ...ust this may cause damage and water leakage in the dispenser Illumination Behind the front panel there is a low energy fluorescent lamp with the effect off 24W The fluorescent lamp is a PL lamp Change low energy lamp Loosen frontplate 4 screws A hold the frontplatte see B Lift out frontplate C and change lamp assemble the frontplate A A A A B C D ...

Page 6: ...c Picture description Drip tray It is possible to connect drainage to the drip tray Large particle filter A large particle filter is fitted between the cooling block and the water valves It is possible to rinse the filter if needed ...

Page 7: ...nsure that nothing is damaged Place the dispenser to it s position Note The dispenser weights about 49 kg Don t lift by door front panel Allow a space of min 40mm around the frame for air circulation Place the machine on a flat level and waterproof surface If necessary adjustment with the adjustable feets ...

Page 8: ...e sort of water isolator in the water line in case of an emergency leakage Connect the power plug to the wall socket Now the compressor starts and the front panel lights up The water pressure is factory adjusted to 2 2 bar which is the correct working pressure Check by pressing and holding one product button and reading the manometer If there is variations adjust by pulling up knob and turn it unt...

Page 9: ...lenoid valve and sliding the tube in from the side fixes the tube Cut the tube to correct length and push it onto the elbow connector on the ejector Place a cup under the outlet pipe Dispense a glass of product by pressing the push button Check that the brix value mixing ratio is okay if not adjust To adjust the brix use the adjustment screw on the ejector The dispenser is now ready to use ...

Page 10: ... 4 Check the tube length so that it will reach 1cm into the venture nipple 5 If the tube is to long cut it to the right length 6 Slip the tube to the venture nipple 7 Make sure that the tube is not twisted and shut the door to the dispenser 8 Place a cup under the outlet pipes and draw until the juice comes out Daily cleaning 1 Clean internal and external surface with a damped rag 2 Use the cleani...

Page 11: ...ith warm water and some washing up liquid and connect it to the venture 3 Shut the dispenser door and put a cup under the outlet pipes rinse the venture and the outlet pipes by pressing the respective push buttons 4 Use the cleaning brush to clean the outlet pipes Return the boxes and connect the tubes to the ventures ...

Page 12: ...t water and a sanitising agent Add two drops of washing up liquid Connect the tube to the nozzle and wash it through Fig 4 3 Wet the brush in a hot water and sterilising solution Clean the outlet pipes by pushing the brush all the way through the pipe and back again Fig 5 4 Rinse the pipes with the water solution from the bottle 5 The pinch solenoid that the tube runs through should be cleaned on ...

Page 13: ...ater The bag is empty Replace bag Nothing happens when I push the buttons and there is no clicking sound No power to the valves Check the valve on off key switch inside the door Thermo fuse in the transformer has cut On older models a fuse has blown Remove power to the dispenser and put it back on after 10 sec Change fuse Nothing happens when you push the buttons and there is a clicking sound Wate...

Page 14: ...ly Clean ejector outlet pipes and pinch solenoid The ejector is not adjusted correctly Dirt in the water valve Call service Call service It constantly drips fluid from the outlet pipes Call service Troubles with cooling system The drinks are not cold Failure in thermostat Call service Failure in cooling system Call service ...

Page 15: ...surement Height 745 mm With 385 mm Depth 560 mm Weight 49 Kg Note 1 The thermostat is factory adjusted and improper adjustment may cause the cooling system to freeze causing damage or water leakage in the dispenser Note 2 It is strongly recommended to use some sort of water isolator in the water line in case of an emergency leakage Note 3 Maximum ambient temperature in the room where the dispenser...

Page 16: ...16 Dimension sketch ...

Page 17: ...no 1704145 FOR SERVICE Please contact your retail dealer Din återförsäljare Your retail dealer COFFEE QUEEN AB Box 960 671 29 ARVIKA besöksadress Korpralsv 1B Tel vxl 46 0 570 47700 Fax 46 0 570 47719 E mail info coffeequeen se www coffeequeen se ...