5831 Series is an extreme-duty, low-energy door opener designed for institutional high-traffic . It allows the door 

to open manually or by a RF transmitter pushbutton . As the door closes, the 5831 Series generates an electrical 

charge that restores power to the battery, eliminating the need for electrical power . 

5831 Series should be installed on doors using our 80/25 guideline: 

• 

 Apply 5831 Series to a door that will be cycled manually a minimum of 80 times per day and cycled 

automatically approximately 25% or less per day .  

Using this 80/25 guideline, the 5831 Series will self-generate all the power it needs to keep its field-replaceable on-

board battery pack charged for up to 12 years or longer . 

A fully charged battery pack can open a door up to 2,500 times in a row with little impact on overall usability 

even if there are periodic fluctuations from the 80/25 guideline . For example 30% automatic use for one day is not 

problematic, provided that level of automatic use is not sustained . 

If the door is operated by wireless RF transmitter pushbutton more often than described in the 80/25 rule, the 

door-closing cycle will not supply enough power to charge the battery pack and permit remote operation . In this 

case, an optional plug-in 24VDC power supply is required . Simply plug the unit into a common 230VAC electrical 

outlet using a plug-in 24VDC power supply .

Operation Upon Loss of Power:

 

Standard installations require no external power and operation will not be affected during a power loss . Typically a 

maximum of 2,500 cycles can be obtained from a fully charged battery pack . Installations with a power supply will 

continue to function normally . 

Operation Upon Obstruction: 

If door meets an obstruction while opening, door will remain under power for one (1) second and then close under 

spring force . If door meets an obstruction while closing, door will maintain a closing force of 3 .6 kg or less . 

General Information

Power Specifications 

Transmitter

•  RF signal range of 10m from either side of door . 

•  One (1) 3-volt 280mAH lithium battery (P/N 

CR2032) provides transmitter power for 

approximately 250,000 activations . 

Power Supply:

•  24VDC power supply converts incoming 230VAC 

power to voltage required by controller using a 

standard 230VAC grounded power outlet .

•  Power Input: 24VDC voltage, current 500mA  

or more 

Содержание ASSA ABLOY 5831 Series

Страница 1: ...mm x4 Wood 12 x 32mm x10 Aluminum Hollow Metal 1 4 20 x 19mm x10 Hex Wrench Through Bolt 1 4 20 x 41mm x4 Arm Spacer x2 Rivetnut Installation Tool Mounting Post x2 Washer x12 9 64 3 16 Push Side Paral...

Страница 2: ...njury Coin Battery Safety Information WARNING KEEP BATTERIES OUT OF REACH OF CHILDREN If the battery is a lithium button coin battery placing the battery in any part of the body or swallowing may lead...

Страница 3: ...not problematic provided that level of automatic use is not sustained If the door is operated by wireless RF transmitter pushbutton more often than described in the 80 25 rule the door closing cycle w...

Страница 4: ...general public limits Battery Safety Information Risk of explosion and personal injury if device is installed into non compatible circuit Do not open mutilate or expose to conducting materials metal...

Страница 5: ...230VAC grounded power outlet is available in vicinity of door Set up a protective barrier caution warning tape to prevent unauthorized access to work area If applicable remove existing door closer Ma...

Страница 6: ...stop Figure 5 This line is shown on template PUSH SIDE Operator and Arm Installation Figure 5 Prepare Door and Frame Figure 4 16mm Minimum 38mm Maximum Greater than 38mm 38mm Or Less 16mm Minimum 38m...

Страница 7: ...ceiling covers face of frame Shoe should then be installed on underside of frame header NOTE If used triangular support bracket face must be flush against face of frame header or frame rabbet Dependin...

Страница 8: ...bracket holes b Using provided rivnut installation tool install bracket to door with minimum four 4 20 steel rivnuts DO NOT TIGHTEN If door is wood or hollow metal a Use 3 8 bit to drill operator mou...

Страница 9: ...ket using a large adjustable wrench Figure 12 Narrow Stile Door Use lower threaded holes in mounting bracket Wide or Medium Stile Door Use upper threaded holes in mounting bracket 2 Install operator m...

Страница 10: ...r and Arm Installation Preload Arm 1 Pull arm elbow 6mm away from face of door to add tension Figure 15 2 While maintaining arm elbow position at 6mm increase or decrease arm length by twisting end li...

Страница 11: ...cations with a center punch and hammer CAUTION On an aluminum storefront door operator mounting holes must not be drilled into top rail web rail to stile tie rod s or rail to stile junction CAUTION To...

Страница 12: ...four 4 20 socket head cap screws and washers DO NOT TIGHTEN NOTE For light duty or hollow core doors with insufficient top rail blocking supplied through bolts or sex nut and bolts are required 2 Usi...

Страница 13: ...ivot bracket hole 3 With arm coupling bolts facing up and end link hole aligned with arm pivot bracket hole place larger end of arm onto pinion shaft Figure 26 4 While maintaining arm position tighten...

Страница 14: ...Battery Pack Press and hold 3 Position switch in OPTION position Green LED fully charged Yellow LED partially drained Red LED fully drained operator will not function in automatic mode NOTE Battery c...

Страница 15: ...ton are mounted between 86 4cm minimum and 121 9cm maximum from floor Reference conformance to requirements set out in AS1428 1 and other applicable building codes for additional information regarding...

Страница 16: ...hen Power Close and or Push and Go features are enabled 1 Route power supply wiring to a 230VAC outlet DO NOT plug power supply into outlet until all connections are made 2 Route wires through end lin...

Страница 17: ...n Operator will store settings and exit programming mode NOTE Refer to Customising Settings beginning on page 19 to adjust settings or enable optional features To reset controller Press and hold ENTER...

Страница 18: ...at a stopped door will apply a force in opening direction of 6 8 kg or less If optional Power Close feature is enabled door shall be adjusted so that a stopped door will apply a force of less than 6 8...

Страница 19: ...ss and release ENTER button to store value 5 Press and hold ENTER button for three 3 seconds to exit programming mode NOTE LEDs will indicate minimum and maximum values as adjustments are made Green i...

Страница 20: ...ON Red LED indicates feature is OFF 3 Rotate thumb wheel to turn feature on or off 4 Press and release ENTER button to store setting 5 Press and hold ENTER button for three 3 seconds to exit programm...

Страница 21: ...e 14 and ensure battery is properly connected to operator Refer to Linking Wireless Pushbuttons page 17 and program RF pushbutton Refer to Programming Operator page 17 and program operator To verify a...

Страница 22: ...Force Can t Remove Battery From Housing Refer to Figure 13 or Figure 27 and note T shaped channel at top of battery housing Insert a small flat head screwdriver into slot above T channel and gently p...

Страница 23: ...sion shown to 165mm Door Stays Open at 90 Degrees Only When Power Operated Refer to Programming Operator page 17 and Auto Set operator When Used Manually Arm Reverses and Does Not Allow Door to Close...

Страница 24: ...d Oakleigh Victoria 3166 Australia info au assaabloy com assaabloyopeningsolutions com au Copyright 2021 ASSA ABLOY Australia Pty Limited All rights reserved Reproduction in whole or in part without t...

Отзывы: