Copyright © 2021, ASSA ABLOY Australia Pty Limited. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Australia Pty Limited is prohibited.
700002AU Rev 2 06/21
14
5831 Series
Installation and Operating Instructions
1 . Make sure 3 Position switch on battery pack
is in OFF position .
2 . Attach battery pack wiring connector to
operator receptacle .
Note:
Connector is keyed to prevent
attaching incorrectly .
3 . Using T channel, slide battery pack onto
operator making sure wires are tucked into
operator cavity and not pinched .
4 . Toggle 3 Position switch to ON position .
3 Position
Switch
Battery
Connector
Auxiliary
Connector
LED
Figure 27
Install Battery Pack
Press and hold 3 Position switch in “OPTION”
position .
• Green LED = fully charged .
• Yellow LED = partially drained .
• Red LED = fully drained (operator will
not function in automatic mode)
NOTE:
Battery can be charged by using a
battery charger, a Plug-In 24VDC power supply,
or by allowing manual traffic to restore battery
power .
Figure 28
3 Position Switch
LED
T Channel
Adjust Door Spring Tension If Necessary
1 . Manually open and close door several times to make
sure door opens and closes smoothly .
2 . If door feels too light, use 3/16" hex wrench to turn
screw clockwise to increase spring tension .
If door feels too heavy, use 3/16" hex wrench to turn
screw counter clockwise to decrease spring tension .
NOTE:
Operator is shipped with spring tension set to
one half of maximum spring tension .
Increase
Spring Force
Clockwise
Decrease
Spring Force
Counter Clockwise
Figure 29
Check Battery Voltage