18
7000INST Copyright Lockmasters, Inc. 5/25/11
step 18 – secure the Inside Base Plate to the door
IF HARDPLATE IS BEING USED - INSTALL NOW
Align the hard plate to the backside of Inside Base Plate and secure with double-sided
tape. Secure by inserting (2) of the metal thread forming screws (F) into the base plate
holes (C) to hold the hard plate in position while securing the Inside Base Plate to the
door (See Figure 6).
Step 18A – To ensure vibration does not loosen the screws over time, we provide a
pack of Liquid Thread Locker (M) for use on the (4) ¼-20x2 ½” socket head machine
screws (E) that are used to secure the Front Plate. Simply place a few drops of the
liquid onto the threads prior to use.
Step 18B – On the Inside Base Plate side of the door, permanently attach the (4)
¼-20x2 ½” (E) screws. These (4) screws will go into the upper 4 (B) holes. (See
photo). Snug only. After all (4) screws are inserted tighten the screws into the lock.
STAND-OFF KIT OPTION – if Stand-off Kit is installed use the (4) shorter ¼-20 socket
head machine screws supplied in the Stand-off Kit, instead of the longer (E) screws.
Step 18C – Remove (2) (H) Phillips heads screws that were previously installed in step
13b. Apply thread locker and re-install.
Step 18D – Install the (4) (F) ¼” Phillips head thread forming screws into (4) C holes.
HarDPlatE oPtIon
– If hardplate was installed install the (2) remaining (F)
¼” Phillips head thread forming screws into (2) C holes.
lKM7000
Installation
18a - Prepping IBP attaching screws with liquid
thread locker (provided).
18b - Attaching IBP to the door.
18c - Remove and apply liquid thread locker to
pre-installed screws holding the front plate into
position and re-install.
18d - Secure the front plate with the remaining
screws through the IBP.
(Figure 6) - HARDPLATE ALIGNMENT IF USED.
Use double-sided tape and align the hardplate with the IBP.
IF hardplate is used.