background image

CX-ED1259-L

‘RIM’ Electric Strike 

Installation Instructions

1. Description 

Camden CX-ED1259-L Grade 1 RIM strike for pullman 

latches offer the very best strike quality and performance. 

The strike design delivers unparalleled application flexibility, 

with field selectable voltage, fail safe/fail secure operation 

and mechanical adjustment of the strike body.

1- 4 PIN power connector
1- 3 PIN door status  

 

 connector
4- Wire nuts 
2- M5 x self tapping screws
4- M6 x 30 screws

2- M5 x 25 screws  

 spacers
4- M2.5 x 4 screws
1- MOV
1- Cover plate 

This Package Includes:

Page 1 of 3

2. Specifications

Voltage

12/24V AC/DC

Current Draw

280mA@12V DC 
140mA@24V DC

Static Strength

1,500 Lbs.

Dynamic Strength

70 Ft-Lbs.

Endurance

1,000,000 Cycles (Factory Tested)  
250,000 Cycles (UL Verified)

Fire Rating

UL 10C/CAN4-S104 
3 hrs. (Fail Secure Only)

Mode

Field Selectable 
Fail Safe/Fail Secure

Mech. Adjustment

Strike Body/Faceplate

Operation

AC-Buzz 
DC-Silent

Duty

Continuous

Latch Bolt Monitor

SPDT, 100mA @ 24V DC

Dimensions (Body)

9” H x 1 3/4” W x 1/2” D 
(230mm x 45mm x 12.7mm)

3. Dimensions

9" [230.0 mm]

134" [45.0 mm]

1

2" [12.7 mm]

UL 1034
Burglary

UL10C/
CAN4-S104,
3hr. Fire rating

Отзывы: